Inspecting the blades and protector
Check and clean the blades and protector daily. If they are worn,
bent and cracked, replace them.
Lubricating moving parts (Fig. 6)
NOTICE: Follow the instruction of the frequency and amount of
grease supplied. Otherwise insufficient lubrication may damage
moving parts.
Gear case:
Fill approx. 30 ml of grease (Shell Alvania S-1 or equivalent)
through the grease port (A) evenly every 50 hours of operation.
Drive axle (B):
Apply grease (Shell Alvania No.2 or equivalent) every 25 hours of
operation.

Maintenance schedule

Operating hour
Whole unit
Visually inspect for
damaged parts
All fixing screws and nuts
Tighten
Blades and protector
Clean and visually inspect
for damaged parts
Gear case
Supply grease
Drive axle
Supply grease
Power unit
Refer to the instruction manual of the power unit

Troubleshooting

Problem
The motor does not start.
The motor stops soon after its start.
The maximum speed is limited.
The blades do not rotate.
Stop the motor immediately!
The unit vibrates abnormally.
Stop the motor immediately!
The blades do not stop.
Stop the motor immediately!

Technical data

Model
Dimensions (L x W x H)
Mass
Cultivating width
Outer diameter of the blades
Gear ratio
Overall inspection

Storage

"Safety precautions" and the instruction manual of the power unit.
(Fig. 7)
When storing the cultivator attachment separated from the power
unit, put the cap onto the end of the shaft.
Before Operation
Probable cause
Refer to the instruction manual of the power unit.
The blades are not installed properly.
Roots or the like are caught in the blades.
The drive system does not work properly.
The blades are not installed properly.
The drive system does not work properly.
The power unit does not work properly.
6
Tighten loose bolts, nuts and screws.
Check for damaged parts and blades. Ask Makita authorized
service center to replace them.
WARNING: Follow the warnings and precautions in the chapter
Daily
25 h
(10 h)
Install the blades properly.
Remove the foreign matter.
Ask Makita authorized service center to
inspect and repair it.
Install the blades properly.
Ask Makita authorized service center to
inspect and repair it.
Refer to the instruction manual of the power
unit.
mm
kg
mm
mm
50 h
Corresponding page
6
6
6
6
6
Solution
KR400MP
965 x 235 x 264
2.9
160
232
1/35