3 For 400-230V earthed three-
phase connection, bridges
connect 4-5 terminals, phases in
succession 1,2 and 3, Neutral to
4-5
Protective ground to
L1=R, L2=S, L3=T
1. Check that the technical data of your energy supply meet the values on the
nameplate.
2. Your domestic circuit must be equipped with an automatic circuit breaker.
3. Do not attempt to repair the appliance yourself. Repairs carried out by
unauthorized persons can cause serious damage. Always contact the nearest service
centre. Original spare parts should be used only..

2.5 Electrical connection of the hob

The hop works with a voltage of 230V AC. The electrical connection gets the power
from the oven. Carry out the connection properly and as described on the drawing
below.
Oven
N= Earth
43
H05VV-F5G1,5
PE= earth wire terminal