14. Calibration Check

Set up the laser leveller as described in point 1 (but on an
extremely well aligned tripod) and align it along a traverse
length of approximately 30 metres – starting with the X
axis, for example – and switch it on.
At the end of the traverse length, make a mark at the level
of the laser beam. After this, rotate the laser unit by 180°
and make another mark. Then do the same for the Y axis.
If all the marks are on top of each other or are only slightly
apart (maximum of 2 mm), adjustment is OK. If the marks
are a long way apart, you must get a specialist firm to
check the equipment and recalibrate it.

15. Menu

Information and settings
Switch on the laser
Press for five seconds
InFo INFO- display
e.g. 1.5 CPU (Program Version)
Sn. (Factory number, 6 digit)
h (Operating hours)
Next menu item
Fb CH9
Automatic channel selection or set manually
EU
Select channel CH 1 – 16. (AUTO: Reserved for auto-
matic selection) Wireless off: OFF
Activate frequency selection (press for 5 sec.)