Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 10
The following conditions may not be breakdowns so check again.
Symptom
Doesn't operate at all:
The operation mode
cannot be changed:
Poor Cooling
(or Heating)
performance:
Set the temperature lower
than the room tempera-
ture and use it:
In the following situations stop operation immediately and get in touch with authorized
service personnel.
G The problem cannot be solved even when the troubleshooting checks have been performed.
G The OPERATION indicator lamp (green) is flashing very fast.
G The wired remote controller or simple remote controller indicate Er (when connected).
G It has burning smell.

SPECIFICATIONS

MODEL
POWER SOURCE
AVAILABLE VOLTAGE RANGE
COOLING CAPACITY
HEATING CAPACITY
SOUND PRESSURE LEVEL
HIGH
MED
LOW
DIMENSIONS & WEIGHT
HEIGHT
WIDTH
DEPTH
WEIGHT
G
Acoustic Noise Information : The maximum sound pressure level is less than 70 dB (A) for both indoor unit and outdoor
9371056036-02_OM_en.p65
G Has there been a power failure?
G Has a fuse blown out, or a circuit breaker been tripped?
G Is the main power switch set to the OFF position?
G Are you trying to engage in an operation different from the priority state?
G Is it in standby state?
G Are you trying to change to an operation different from the priority conditions?
G Did you adjust the room temperature settings (thermostat) correctly?
G Is the air filter dirty?
G Are the air conditioner's inlet port or outlet port blocked?
G Is there a window or door open?
G In the case of Cooling operation, is a window allowing bright sunlight to enter?
(Close the curtains.)
G In the case of Cooling operation, are there heating apparatus and computers
inside the room, or are there too many people in the room?
G Is the fan speed set to low?
G Temperature does not fall down well.
Temperature may not fall down depending on the room conditions.
(While high humidity or the room temperature is high.)
AS A18L
[kW]
5.60
[kW]
6.30
dB (A)
43
dB (A)
37
dB (A)
30
[mm]
[mm]
[mm]
[kg]
unit.
According to IEC 704-1 and ISO 3744.
8
Items to check
AS A24L
230 V~50 Hz
198 to 264 V
7.10
8.00
45
39
33
320
1,120
220
16
5/2/09, 13:03
See page
4
4
4
5
4
AS A30L
8.00
8.80
45
42
39
En-8

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis