1. Connect the midspan (data in) to the network switch using a network cable.
2. Connect the midspan (data and power out) to the camera using the network cable that
has been connected to the camera.
3. Connect the midspan to a grounded (earthed) mains power outlet (100–240 V AC) using
the supplied power cable.
1
Data and power out (connect to Axis product)
2
Data in (connect to network)
3
AC input LED indicator
4
Port LED indicator
4. Make sure that the LEDs on the midspan indicate the correct conditions. See Midspan
LED Indicators on page 12.

Access the Product

Use the tools provided on the Installation and Management Software CD to assign an IP address,
set the password and access the video stream. This information is also available from the support
pages on www.axis.com/techsup/

Reset to Factory Default Settings

Important
Reset to factory default should be used with caution. A reset to factory default will reset
all settings, including the IP address, to the factory default values.
Note
The installation and management software tools are available on the CD supplied with the
product and from the support pages on www.axis.com/techsup