5.3.3
Checking memory module for rail detection
(one-wire chip)
The software detects the current rail configuration
by way of the memory module. The rail configuration
information (emergency shut-off pressure, maximum
pressure etc.) is loaded at the factory and cannot be
altered.
Memory module read-out:
1. Switch on the EPS at the master switch.
2. After booting of the PC, start the application
EPS945-PE/VE/CR in the Bosch applications list.
? The "Injection component test main menu"
window is called up.
? The application performs initialization.
3. In the "Injection component test main menu"
window select <F7>.
? A password request appears.
4. Enter the password in the input line:
5. Confirm the entry with <F12>.
6. Select the menu item "Calibration >> Rail pressure
sensor".
? The "Rail pressure sensor calibration" window is
called up.
7. Select <F2>.
? The memory module information is called up
(refer to illustration).
Robert Bosch GmbH
Proceed as follows if the configuration 99999 is
displayed on reading out the memory information
(refer to illustration):
R
Check the connecting cable to the memory module
for continuity.
R
Replace the memory module if the connecting cable
is OK.
1958
The following configurations are possible:
Configu-
ration
1 - 99995 Configuration OK
99996
99997
99998
99999
Trouble-shooting | CRS 845H | 55
Fault
Remedy
None
Firmware does
Install latest firmware version
not detect current
configuration
Empty memory
None
module (replacement
part).
R Start firmware download
CRC error
(checksum)
with <F3> (under
Configuration >>
Calibration >> Rail
pressure sensor)
R Replace the memory
module
R Check the connecting
Memory module is
not detected
cable to the memory
module for continuity.
R Check whether the
shorting plug X 15 is
connected to the
control device.
R Replace the memory
module.
1 689 975 229