5.

Trouble-shooting

5.1

Control device

!
Heed the handling instructions relating to ESD when
working on open devices. These instructions can be
found in EDIS under "Bosch Test Equipment >> Test
systems AZ >> General information >> Safety".
The trigger PCB A10 is accommodated in the housing of
the control device.
V14 V11
LP472
A10
X14
X9
X7
Light-emitting diodes (LEDs) located on the trigger PCB A10 indicate the status of the test system, provided that
the EPS is switched on at the master switch.
If there is no fault in the test system, the LEDs on the trigger PCB must light as follows with the splash guard
doors closed:
V11
V14
V19
V21
V24
Symbol
Key
LED on
LED off
LED flashing
LED lights dimly
LED lights for 1 second
(1 sec.)
|
1 689 975 229
2011-09-16
X4
X2
X1
V27
V26
V24
V19
K1
K4
K2
V23
K3
V22
V21
F3
F2
F1
X4
X10
X12
X3
458857-07_Pal
V26
V27
Cause
No faults occurred.
All splash guard doors closed.
F1
Fuse (8 A, slow-blow)
F2
Fuse (8 A, slow-blow)
F3
Fuse (1 A, medium time lag)
V11
180 / 250 MPa rail differentiation
(180 MPa = off, 250 MPa = on)
V14
Validity of rail configuration
V19
12 V power supply on/off for relay K1
V21
24 V power supply on/off for relay K2
V22
12/24 V switching for relay K3
(PWM channel 2 for DRV, DMV, ZME)
V23
12/24 V switching for relay K4
(PWM channel 3 for EAV, DMV2)
V24
Microcontroller indicator
V26
Regulated 12 V supply
V27
Regulated 5 V supply
X1
Communication connector LP 472
X2
Connector for pressure sensor B9
X4
Connector (LP 472) for memory module detection
and temperature sensor
X3
Serial interface
X4
Connector for power supply (12/24 V)
X7
Connector for door monitoring (X3)
X9
Connector for pump-specific connecting cable
X10
Communication connector LP 472
X12
Connector for pressure sensor B10
X14
Connector for door monitoring (X4)