Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch BSA / SDL 4 Series Originalbetriebsanleitung Seite 52

Prüfstraße mit pc für pkw
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
52 | BSA 43xx | Manual mode (normal operation)
Step
5. Braking force measurement:
Slowly and steadily depress brake
pedal until maximum braking force
(slip) is attained.
Release brake pedal again.
i
Shut-off criteria:
$
Wheel lock-up (slip monitoring).
$
Motorcycle drift (touch roller no
longer pressed).
$
Maximum braking force (slip) not
attained on braking and braking
action remains at rolling resistance
level for more than six seconds.
6. End of measurement for tester
without motor brake.
Start of measurement
Drive motorcycle off set of rollers.
|
1 691 606 210
2015-07-29
Remote control
Result / Display
 The current values are displayed on the screen:
$
Braking force (F)
$
Pedal force (PD)
$
Braking factor (Z)
 Peak value display (approx. 5 seconds).
"
The measured values can now be stored.
"
Braking force measurement over.
+
+
Robert Bosch GmbH

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis