TOF: Setting Mode – for setting the offset temperature
The temperature is measured at the heating appliance
itself, with the result that other parts of the room may be
warmer or colder than this. To allow for this, you can set a
temperature offset of ±3.5°C. If, for example, a tempera-
ture of 18°C is measured somewhere within the room
instead of the 20°C set, it means that an offset of -2.0°C
needs to be configured.
1. Press the menu button until TOF is displayed and
confirm with OK.
2. Use the setting wheel to modify the temperature and
press OK button to confirm.