Tab. A
Technical Specification
Max dimension Bracket model
Max dimension Frame model
(height x width x depth)
Metal-Plastic storage tank dimensions
(height x width x depth)
Weight Bracket models
Weight frame models
Max daily producion 50 GPD
Percent recovery
Saline rejection
Bacterial rejection
Max. feed water TDS
Max. feed water temperature
Min feed flow
Min feed pressure
Max feed pressure
Electric power
Rated voltage
Frequency
Absorbed current
Power
Power type
Rated voltage
Head
2.5.1 Typical installation with 1/2" MF water intake
- Unscrew the cold water hose nut from the wall coupling.
- With sealing tape (PTFE), install the 1/2" MF water intake with the 1/4" tap.
- Reassemble the previously detached hose on the water intake male.
- Connect the OASIS 1/4" hose to the water intake.
2.5.2 Drain bracket installation
- Install the drain bracket on the sink drain siphon.
- Make sure the gasket correctly rests on the pipe
and that the bolts are tight.
- Remove the drain pipe fastening nut.
- Using a drill with a 6mm bit, drill a hole on the
drain siphon pipe where the nut was just re-
moved.
- Insert the drain pipe in the nut by about 2 cm and
screw the fastening nut onto the bracket.
- Tighten the fastening nut and install the check
valve with the arrow facing the bracket, as close
to the drain as possible.
2.5.3 Storage tank installation
- Place the tank near the machine.
- Loosen the fastening nut on the tank ball valve.
- Insert the 1/4" tank connection pipe and tighten
the fastening nut.
- Connect the 1/4" pipe to the machine.
2.5.4 Dedicated tap installation
- Drill a 12mm diameter hole on the sink bottom
(no. 6), remove any burrs with a round file.
- Place the gasket (no. 5) with spacer (no. 4) and
chrome-plated base (no. 3) on the hole, insert the
threaded tap rod (no. 2).
- ON the bottom side, insert in order the gasket
(no. 7), elastic washer (no. 8) and screw in the
fastening nut (no. 9).
- Insert the pipe (no. 12) in the end nut (no. 11) and
plastic ring (no. 10).
- Tighten the end nut (no. 11) on the threaded tap
rod (no. 2).
1. Tap
2. Threaded tap rod
3. Chrome-plated base
Unit of Measure
STD
UV
mm
490x390x180
490x390x180
mm
mm
280x380
280x380
kg
6,5 Kg
7 Kg
kg
L
190
190
%
30
30
%
97
97
%
>98
>98
mg/l (ppm)
1000
1000
˚C
45
45
l/h
100
100
bar
3
3
bar
8
8
Single phase
+ Grounding
V
230/220
Hz
50
A
0,80 -0,03
W
6
V
psi
1. Drain pipe
2. Quick coupling
3. Drain bracket
4. Gasket
5. Bolt
6. Bolt lock nut
7. Sink drain siphon pipe
4
5
8
9
12
PUMP
PUMP UV
520x390x180
550x390x180
520x390x225
520x390x225
280x380
280x380
9 Kg
10 Kg
13 Kg
14 Kg
190
190
30
30
97
97
>98
>98
1000
1000
45
45
100
100
1
1
8
8
Single phase
+ Grounding
230/220
50
0,80 -0,03
6
Direct current
Direct current
24
24
125
125
Ø 6 mm
2
3
5
1
2
3
6
7
10
11
1
4
7
6
13