Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Dear Costumer, thanks for choosing this Atlas Filtri
EN
1. GENERAL INFORMATION
The indications in this manual apply to models:
OASIS SANIC STD - OASIS SANIC PUMP - OASIS SANIC UV - OASIS SANIC PUMP-UV - OASIS F SANIC PUMP - OASIS F SANIC PUMP-UV
OASIS SANIC is a device intended to process drinking water able to modify its organoleptic and chemical properties, reducing the saline content while guaranteeing
microbiological safety. Correct use and maintenance permit the reduction of most pollutants such as insecticides, pesticides, fertilisers, hazardous organic substances,
heavy metals, pathogen micro-organisms.

1.1 CONDITIONS OF USE

- OASIS SANIC is not a drinking water maker. Do not use for uses intended for drinking water in the event of originally non-drinking water or of unknown quality.
- Perform periodic routine maintenance to guarantee processed water drinking requirements and maintain the stated performance levels.
- In the event of prolonged disuse, remove the cartridges and membranes and, when reused, insert new ones. After servicing, let the water run for at least 5 minutes
before using it.
- At the end of the OASIS device working life and relevant cartridges, membranes and UV lamps, discard according to current local law.
PRELIMINARY PRODUCT PREPARATION
The 1-2-3 labels indicating the three pre-filtration stages are supplied
not attached to the product but positioned inside the provided bowls,
it will be the user's responsibility to apply them correctly by following
these simple steps:
1. Remove the label nr.1 and the sealed cartridge (FA 25 µm) from
the bowl.
2. Remove the transparent film from the cartridge, place the cartridge
inside the bowl.
3. Lubricate the bowl o-ring with the lubricant included in the package
(Lubrikit+). If the o-ring appears damaged, replace it with a new o-ring
(o-ring included in the package) and lubricate with Lubrikit+.
4. Screw the bowl onto the head and tighten with a wrench, do not
over-tighten.
5. Once the bowl has been correctly screwed to the head, apply the nr.1
label onto the front of the bowl.
6. Repeat the same operation for the next stages of filtration (nr.2 CPP
5 µm and nr.3 CB-EC)
7. The correct configuration will so be (starting from left to right) 1 = FA
/ 2 = CPP / 3 = CBEC.
WORKING CONDITIONS
pH: 6,5 – 9,5
Max working pressure: 8 bar (116 psi)
Min working pressure: 3,0 bar (43,5 psi)
1,0 bar (14,5 psi) PUMP models only
Max working temperature: 45°C (113 °F)
Water appearance: transparent
Max Hardness: 35°F (350 ppm CaCO
)
3
Max Iron: ≤ 0,2 ppm
Max Manganese: ≤ 0,05 ppm
Max Chlorine: ≤ 0,3 ppm
Organic matter: absent
Total dissolved solids: 1000 ppm
Min / Max water temperature: 4°C / 45°C
WARNING
At the start and after every maintenance operation, when the unit's bowl is unscrewed from head, change the o-ring with a new one and carefully lubricate with original
lubricant Lubrikit+ before tightening the bowl to the head. Make sure that there are no water leaks from the product, and especially control the tightening between the
housing head and the housing bowl.
Continue checking that the tightening is good and there is no water leakage for 48 hours following the Installation and start-up. In case of leakage, open the housing, remove
the o-ring from the bowl, place a new o-ring and apply original lubricant Lubrikit+, then re-tighten the bowl to head and repeat the leakage check as above.
Use only original Atlas Filtri o-rings otherwise the warranty is void. Ask your Vendor for original o-rings, Lubrikit+ and other spare parts.
Remark: after the maintenance, slowly turn on a water supply (tap) downstream the installed unit and let the water flow for at least 5 minutes before the use.
Using cartridges other than original ones voids the warranty
2. INSTALLATION
2.1 Introduction
Assembly and installation must be performed by qualified personnel according to current local regulations. Before performing any operation, carefully read the instructions
in this manual. Keep the manual and protect it against anything that could compromise its legibility.
2.2 Main components
1 DP TRIO SANIC head for housings for filter cartridges
2 DP TRIO SANIC housing bowls for filter cartridges
3 RO VESSEL SANIC housing for osmosis membrane
product.
®
inlet
CLEAR
BOWL
Manual Flush Valve
OPAQUE
BOWL
11