USING YOUR SONAIR

3.1 Ventilation using manual operation

EN
You can set the ventilation rate of your Sonair manually using the two operating
buttons at the top of the unit. By pushing the right button you can increase the
DE
fan speed. By pushing the left button you can decrease the fan speed and stop
the motor. The ventilation rate is variable from 0 to 225 m
rates for one and two persons are marked on the display.
The ventilation rate depends on the filter type and the diameter of the duct.
The markings are based on the standard version of the Sonair, which has a
G3 filter and a duct with an inner diameter of 100 mm. The table below shows
how many cubic metres of air per hour are supplied for each type of filter and
diameter of the duct at every position of the indicator bar.
Diameter duct:
100 mm
Diameter duct:
120 mm

3.2 Replacing the filter

We recommend that you replace the filter in your Sonair every 6 to 9 months
or when the filter indicator appears. More information about the types of filter
can be found on page 23. The old filter can be disposed of with the household
rubbish.
Remove the power cable from the power socket before replacing the filter.
20
MAX
MAX
G3-Filter
26
30
F6-Filter
15
17
G3-Filter
29
33
F6-Filter
18
20
3
= ventilation rate for 1 person
= ventilation rate for 2 persons
= maximum ventilation rate
45
60
75
90
105
28
38
50
61
71
48
62
77
92
108
30
40
51
62
73
/h. The ventilation
120
140
162
225
83
100
116
-
124
147
167
-
86
103
120
-