3.3 Settings
Set the input / output range using DIP
switches S1 and S2 as indicated in the
table
Input
Output
0 to 20 mA
0 to 20 mA
0 to 20 mA
4 to 20 mA
0 to 20 mA
0 to 10 V
4 to 20 mA
0 to 20 mA
4 to 20 mA
4 to 20 mA
4 to 20 mA
0 to 10 V
0 to 10 V
0 to 20 mA
0 to 10 V
4 to 20 mA
0 to 10 V
0 to 10 V
Bandwidth 10 Hz
Bandwidth 10 kHz
X without influence on this setting
Selected range can be documented on rating plate and front label.
Factory setting: 0 to 20 mA / 0 to 20 mA, 10 kHz