Bosch Rexroth AG

Input/Output array

6
Input/Output array
6.1

Serial input/output field

Serial input field
Tabelle 12:
Bits
Inputs
1.0
External weld on
1.1
General Fault Reset
1.2
Weld Contactor Enable
1.3
End of component
1.4
Link to discrete output A_2
1.5
Free
1.6
Start
1.7
Acknowledge all tips changed
1.8
Spot selection 1
1.9
Spot selection 2
1.10
Spot selection 3
1.11
Spot selection 4
1.12
Spot selection 5
1.13
Spot selection 6
1.14
Spot selection 7
1.15
Spot selection 8
Serial output field
Tabelle 13:
Bits
Outputs
1.0
No minor fault / No warning
1.1
Electrode prewarning
1.2
Max. electrode life
1.3
Free
1.4
Free
1.5
Free
1.6
Free
1.7
Free
1.8
Timer ready
1.9
Firing enabled (Copy of serial input 1.0 "External weld on")
1.10
End of Sequence (EOS)