Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Instructions; General Description - RECHNER SENSORS K 130-Serie Bedienungsanleitung

Trennschaltverstärker mit transistorausgang
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

General Description • Technical Data

Safety Instructions:

• The temperature class and explosion group as well as the special conditions marked on the devices have
to be observed!
• Modifications of the amplifier or changes of its design are not permitted.
• Place of installation must be in a safe area in an enclosure, degree of protection min. IP 20
• The device has to be used for its intended purpose and in a perfect and clean condition.
• For replacement and repair only genuine RECHNER spare parts may be used.
• Prior to its taking into operation the amplifier will have to be checked in accordance with the instructions
as per section "Installation".
• Observe the national safety rules and regulations for prevention of accidents as well as the safety
instructions included in these operating instruction.
• The amplifier is not suitable for mounting in zone 0, 1, 2 or zone 20, 21, 22 areas!
Short Description
The switch amplifier serves as an interface between electrical signals of the hazardous areas to the safe
areas. The input signals of NAMUR initiators, mechanical contacts or optocouplers are transmitted through
transistor contacts. The input-, output- and power supply circuits are safe galvanic
circuits of this switching amplifier are suitable for Zone 1, 2, 21 and 22.
Scope
EMC – Electromagnetic Compatibility according to EN 60079-0:2011, EN 61000-6-2:2011, EN 61000-6-3:2011
and EN 60947-5-6:2000 (NAMUR)
1.
The unit is designed to be used in an industrial environment.
2.
According to EN 61000-6-2:2011
Criterion A: Switching outputs do not change state in the event of EMC
Technische Daten
This amplifier is approved as associated device.
All regulations of the approval of the country of location
have to be observed.
Explosion category:
Declaration of conformity according 2014/34/EU
CE-Type Examination CE 0158
Certificate Number ATEX:
Marking:
Certificate Number IECEx:
Marking:
Certificate Number CCC:
Marking:
Following norms have been used:
IEC 60079-0:2011, IEC 60079-11:2011, DIN EN ISO 9001
Please note: The conditions of the EN 50281-1-2 e.g. relating to dust-
coating and temperatures must be met.
BVS 17 ATEX E 106 X
II (1) G [Ex ia Ga] IIC,
II (1) D [Ex ia Da] IIIC
BVS 04/2019X
[Ex ia Ga] IIC
[Ex ia Da] IIIC
2021312310000384
[Ex ia Ga] IIC
[Ex ia Da] IIIC
separated.
The intrinsically
11

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis