9. Specifications
Model F1814
Rated force F
N
nom
Rated force F
lbf
nom
Relative linearity error d
Relative reversibility error v
Relative span in unchanged
mounting situation b
Limit force F
L
Breaking force F
B
Material of the measuring body
30 N
≥ 50 N
Service temperature range B
Input resistance R
e
Output resistance R
a
Insulation resistance Ris
Output signal (rated characteristic
value) C
nom
Electrical connection
Voltage supply
Ingress protection (per IEC/EN 60529) IP64
Weight
Dimensions in mm [in]
Model F1814
SR = spherical radius
Dimensions in mm [in]
Rated force
in N [lbf]
ØA
50 [11.24]
1.5
100 [22.5]
[0.06]
2
200 [45]
300 [67.44]
[0.08]
500 [112]
2.5
1,000 [225]
[0.1]
WIKA operating instructions, models F1811, F1814, F1818, F1821, F1848
50
11.24
1 % F
lin
0.5 % F
0.5 % F
rg
120 % F
150 % F
Aluminium
Stainless steel
-20 ... +80 °C [-4 ... +176 °F]
T, G
1,030 ±80 Ω
1,030 ±80 Ω
≥ 5,000 MΩ/DC 100 V
1.0 ±0.1 mV/V
Cable Ø 2 × 3,000 mm [Ø 0.1 in x 118 in]
DC 5 V (max. 7 V)
0.1 kg [0.22 lbs]
ØB
SR C
D
10
5
6
[0.39]
[0.19]
[0.24]
8
[0.31]
10
[0.39]
100
200
22.5
45
nom
nom
nom
nom
nom
E
F
5.2
50
[0.20]
[1.97]
300
500
1,000
67.44
112
225
G
ØH
L
150
8
3,000
[5.90]
[0.31]
[118]