Terminal strips on the bottom of the instrument
X5
GND
Terminal Use
Analog
Analog
X4/AI1
inputs
i
t
X4/AI2
X4/AI3
Analog
X4/AOV
outputs
p
X4/AOI
X4/A⊥
System bus
System bus
X5/GND
(CAN)
(CAN)
X5/LOW
X5/HI
qáé>
A detailed description of how to invert the digital input and output levels can be
found in the section "DIGITAL_IO" of the Manual for the Drive PLC Developer Studio
(DDS).
Use the function block L_AIN or L_AOUT to adjust the analog input and output
signals. A description of this can also be found in the section "Standard Library
9300 Servo PLC" of the DDS Manual.
L
LOW
HI
Abb. 1-19
120
PES
Freely assignable input 1
Freely assignable input 2
Freely assignable input 3
Voltage output
Current output
Ground for analog inputs
and outputs
CAN-GND
CAN-LOW
CAN-HIGH
EDK10200EV3 DE/EN/FR 5.0
Control connections
X4
AI1
AI2 AI3
CAN-CG
CAN-LO
CAN-HI
Level
-10 V ... +10 V
10 V ... +10 V
-10 V ... +10 V / max.
2 mA
-20 mA ... +20 mA
-
Reference potential
System bus LOW
(data cable)
System bus HIGH
(data cable)
A
AOV AOI
Data
Resolution: 10 bit + sign
Resolution: 10 bit + sign
Resolution: 10 bit + sign
Accuracy: ±0.5 %
Accuracy: ±0 5 %
-
-
-
-
P
plc003