Herunterladen Inhalt Inhalt Diese Seite drucken

IN & OUT HOUSE EF449A Bedienungsanleitung Seite 46

Elektrokamin
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
EN
R E S E T TI N G T H E T H E R M A L C U T O U T
The appliance is fitted with an Electronic Safety Control (E.S.). This is a
safety device which switches off the fire if, for any reason, the appliance over-
heats, e.g. when covered. If the heater stops operating while the flame effect
continues working normally, this indicates that the E.S. Control is in operation.
The E.S. Control can only be reset after the appliance has cooled down,
and the appliance has been reset. Resetting of the E.S. Control proceeds
as follows:
1.
Press button S TA N D BY on the appliance to turn it off and leave it off for
approximately 10 -15 minutes.
2.
Remove any obstruction to the fan heater outlet or fan blades etc.
Make sure that the power supply is disconnected with the plug socket
outlet while doing this.
3.
Switch on the appliance and the E.S. Control will be reset.
4.
Ensure that the appliance is functioning correctly. If the E.S. Control
operates again, the appliance should be checked by a
competent electrician.
A DA P TI V E S TA R T C O N T RO L
Learning from the previous heating cycle enables the appliance to judge the
appropriate advance time to turn on the heater to ensure that the set
temperature is reached at the set time. For example, if your timer is set to
star t at 18:00 and temperature is set to 23 °C, the fire may for example come
on at 17:30 to ensure the room is 23 °C at 18:00.