MANUAL RETURN OF COUPLING TOOL BE32 18 V

If the machine must be brought back to initial
position without completing the stroke, follow
these simple steps:
1. Unscrew protection nut located on the
emergency return device (C) as indicated in
picture 7.
2. Overturn the protection nut and screw
it (by the special threaded hole) to the
emergency return device (C) (picture 8).
3. Pull protection nut downward until the
equipment is released (picture 9).
4. Unscrew protection nut, overturn it and
screw it back in order to restore its initial
position.
5. Restart work.
26
Picture 7
Picture 8
Picture 9