6. Maintenance and inspection

6.1

Safety measures

Important!
i
The operator must provide any protective clothing that may be required.
Who can carry out maintenance and inspection work?
» Normal maintenance work may be carried out by operational personnel.
6.2

Maintenance and inspection table

Assembly
If required Outside of the container
Container
Every
month
Piping system
6.3

Troubleshooting

Fault
Pump does not run with
inserted battery
Pump does not run with
inserted battery
Pump does not run with
inserted battery
Pump is switched on but
does not run
The tank contracts during
use
Pump running, but little or
nothing is being delivered
Contact spring
Action
Clean off any dirt or thawing agent
Visual check for damage
Check hoses for cracks and porosity, check fittings for leaks
(replace defective parts)
Possible cause
Battery empty
Battery inserted incorrectly
Contact springs are soiled
or bent
10 A blade fuse to DIN
72581 faulty
System is pressurized. The
pump's pressure switch
switched off
Ventilation cap closed
Air in the system, or the
spray caddy is empty
Location of the blade fuse in battery housing with switch (shown
from below)
Solution
Recharge battery
Insert battery with terminals pointing down
Clean or straighten the contact springs
Blade fuse is located in the battery hou-
sing. Undo four screws and replace the
fuse
Open the spray lance's trigger handle. The
pressure falls and the pump starts up
Unscrew the ventilation cap in screw
cap a
Fill the spray caddy
GB
Strain relief
Housing with 10 A bla-
de fuse to DIN 72581
Kontaktfeder
15