WITA HE OEM 4 | 40-XX I 60-XX I 80-XX
ORIGINAL
D
BETRIEBSANLEITUNG
SEITE 2–29
TRANSLATION OF
GB
ORIGINAL OPERATING INSTRUCTIONS
PAGE 30–57
TŁUMACZENIE ORYGINALNEJ
PL
INSTRUKCJI OBSŁUGI
STRONA 58–85
|
|
www.wita.de | www.wita.pl

Werbung

Inhaltsverzeichnis
loading

Inhaltszusammenfassung für WITA HE OEM 4 40-Serie

  • Seite 1 WITA HE OEM 4 | 40-XX I 60-XX I 80-XX ORIGINAL BETRIEBSANLEITUNG SEITE 2–29 TRANSLATION OF ORIGINAL OPERATING INSTRUCTIONS PAGE 30–57 TŁUMACZENIE ORYGINALNEJ INSTRUKCJI OBSŁUGI STRONA 58–85 www.wita.de | www.wita.pl...
  • Seite 2: Inhaltsverzeichnis

    2.9 Unzulässige Betriebsweisen ........................8 Transport und Lagerung ......................8 Bestimmungsgemäße Verwendung ...................8 Produktinformationen ......................... 9 5.1 Technische Daten WITA HE OEM 4 | 40-XX I 60-XX I 80-XX ............9 5.2 Lieferumfang ............................. 10 Beschreibung der Pumpe ......................11 Pumpeneinstellung ........................11 7.1 Die Taste...
  • Seite 3: Eu Konformitätserklärung

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX EU KONFORMITÄTSERKLÄRUNG Name des Ausstellers: Wita Sp. z o.o. Display HE Pumpen Zielonka, ul. Biznesowa 22 86-005 Białe Błota Gegenstand der Erklärung: Heizungsumwälzpumpen Typ: WITA HE OEM 4 Ausführung: 40-XX, 60-XX, 80-XX Wir erklären in alleiniger Verantwortung, dass die oben genannten Produkte, auf...
  • Seite 4: Sicherheitshinweise

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 2 Sicherheitshinweise 2.1 Allgemeines Diese Einbau- und Betriebsanleitung ist Bestandteil des Produktes und enthält grundlegende Informationen, die bei Montage, Betrieb und Wartung zu beachten sind. Aus diesem Grund muss sie unbedingt vor der Aufstellung vom Monteur und dem zuständigen Fachpersonal bzw.
  • Seite 5: Personalqualifikation

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Hier stehen nützliche Hinweise zur Hinweis Handhabung des Produktes. Sie machen auf mögliche Schwierigkeiten aufmerk- sam und sollen für einen sicheren Betrieb sorgen. Direkt am Produkt angebrachte Hinweise wie zum Beispiel: •...
  • Seite 6: Gefahren Bei Nichtbeachtung Der Sicherheitshinweise

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 2.4 Gefahren bei Nichtbeachtung der Sicherheitshinweise Werden die Sicherheitshinweise nicht beachtet, kann dies eine Gefährdung von Personen, Umwelt und Anlage zur Folge haben. Die Nichtbeachtung der Sicherheitshinweise führt zum Verlust jeglicher Schadenersatzansprüche.
  • Seite 7: Sicherheitshinweise Für Montage Und Wartungsarbeiten

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX • Gefährdungen durch elektrische Energie müssen ausgeschlossen werden. Hierzu sind z. B. die Vorschriften des VDE und der lokalen Energieversorgungsunternehmen zu beachten. Display HE Pumpen • Sollten an der Anlage Gefahren durch heiße oder kalte Teile auftreten, so müssen diese mit einem Berührungsschutz...
  • Seite 8: Unzulässige Betriebsweisen

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 2.9 Unzulässige Betriebsweisen Wird die Pumpe vom Netz getrennt, muss vor Wiederein- schalten eine Wartezeit von mindestens 1 Minute eingehalten werden. Die Einschaltstrombegrenzung der Pumpe ist sonst wirkungslos und es kann zu Funktionsstörungen, oder Beschädigungen eines evtl.
  • Seite 9: Produktinformationen

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 5 Produktinformationen Technische Daten HE OEM 4 I 40-XX I 60-XX Kennlinie HE OEM 4 | 40-XX Kennlinie HE OEM 4 | 60-XX 40-XX 60-XX Maximale Förderhöhe 4,0 m 6,0 m Maximaler Durchfluss...
  • Seite 10: Lieferumfang

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Technische Daten WITA HE OEM 4 I 80-XX Kennlinie HE OEM 4 | 80-XX 3,5 Qm 80-XX Maximale Förderhöhe 8,0 m Maximaler Durchfluss 4000 l/h Leistungsaufnahme P1 (W) 65 W...
  • Seite 11: Beschreibung Der Pumpe

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 6 Beschreibung der Pumpe In einem durchschnittlichen Haushalt werden 10 bis 20% des Stromverbrauchs durch herkömm- liche Standardpumpen verursacht. Mit der Pumpenserie HE OEM 4 haben wir eine Umwälz- pumpe entwickelt, die einen Energieeffizienzindex von ≤...
  • Seite 12: Auswahl Der Betriebsart Und Betriebsstufe

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Auswahl der Betriebsart und Betriebsstufe 1. Konstantdrehzahlregelung I, II und III In dieser Betriebsart arbeitet die Pumpe über die gesamte Kennlinie mit konstanter Drehzahl. 2. Konstante Druckregelung CP 1, CP 2, CP 3 Bei dieser Art der Steuerung wird der von der Pumpe erzeugte Druck konstant gehalten.
  • Seite 13 Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Bei Auslieferung wird die Pumpe auf die AUTO Smart Adapt Betriebsstufe eingestellt. Durch wiederholtes kurzes Drücken der Auswahltaste werden die Betriebsarten: konstante Drehzahl, konstanter Druck, Proportionaldruck und AUTO Smart Adapt kontinuierlich durchge- schaltet.
  • Seite 14: Empfehlungen Zur Auswahl Der Betriebsstufe

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 7.4 Empfehlungen zur Auswahl der Betriebsstufe Optimale weitere mögliche Einstellung Einstellungen Fussbodenheizung Auto Zweistrangheizsysteme Auto Einstrangheizsystem Auslieferungszustand = AUTO Smart Adapt...
  • Seite 15: Optionale Sonderfunkton Pwm

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 8 Optionale Sonderfunktion PWM Optionale Sonderfunktion PWM Eingang Diese Funktion erlaubt die Drehzahlregelung der Pumpe durch eine externe Steuerung. Display HE Pumpen Um diese Funktion nutzen zu können, muss die Pumpe mit einem entsprechenden Eingang ausgestattet sein.
  • Seite 16 Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Die Leitungslänge darf maximal 3m betragen. Die Signalleitung ist durch einen Optokoppler galvanisch von der Pumpenelektronik getrennt. Das PWM Anschlusskabel ist für einen Betrieb an einer Betriebsnennspannung von 230 VAC auszuführen.
  • Seite 17 Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Beim PWM-Steuersignal handelt es sich um ein Digitalsignal, bei dem die Drehzahlinformation in der Impulsbreite enthalten ist. Das Steuersignal muss folgenden Anforderungen entsprechen: Beispiel eines 40% PWM Signals: T = 1 ms (1 kHz)
  • Seite 18 Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Abfallzeit Anstiegszeit...
  • Seite 19: Heizungskennlinie

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Heizungskennlinie Im Bereich zwischen 0 und 5% des PWM Signals arbeitet die Pumpe aus Sicherheitsgründen mit maximaler Drehzahl. Im Falle eines Fehlers in der PWM Steuerung oder bei einem Kabelbruch ist hierdurch sicherge- Display HE Pumpen stellt, dass die vom Wärmeerzeuger produzierte Wärme weitergeleitet wird.
  • Seite 20: Pwm Rückmeldesignal (Volumenstrom)

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX PWM Rückmeldesignal (Volumenstrom) Durch das PWM Rückmeldesignal ist es möglich, Information des Betriebszustandes der Pumpe an eine Externe Steuerung zu übertragen. Es enthält Informationen zum aktuellen Volumen- strom und zu Fehlerzuständen der Pumpe. Das Ausgangssignal hat eine feste Frequenz von 75Hz und ist von der übrigen Pumpenelektronik galvanisch getrennt.
  • Seite 21 Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Übersicht über die Definition der Ausgangssignale Beschreibung Definition PWM-Kabel nicht angeschlossen oder Kein PWM Signal Pumpe vom Stromnetz getrennt. Pumpe wird durch PWM-Signal Pumpe gestoppt gestoppt Pumpe läuft einwandfrei, Volumenstrom- 5-70 Pumpe läuft...
  • Seite 22: Anlage Füllen Und Entlüften

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 9 Anlage füllen und entlüften Anlage sachgerecht füllen und entlüften. Um die Pumpe zu entlüften, sollte die Hinweis Elektronik auf Stufe III gestellt werden und für mindestens 20 Minuten in dieser Stellung laufen.
  • Seite 23: Verhältnis Zwischen Pumpeneinstellung Und Leistungsverhalten

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 10 Verhältnis zwischen Pumpeneinstellung und Leistungsverhalten Das Verhältnis zwischen Pumpeneinstellung und Leistungsverhalten ist mit Kennlinien angegeben AUTO AUTO 11 Leistungskennlinien HE OEM 4 | 40-XX HE OEM 4 | 60-XX...
  • Seite 24: Montage

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 12 Montage Korrekte Einbaulage des Motors Spannungsfreie Montage mit waagerecht liegendem Pumpenmotor durchführen (Richtungspfeil auf dem Pumpengehäuse zeigt die Flussrichtung an). Bei Wärmedämmarbeiten darauf achten, dass der Pumpenmotor und das Elektronikgehäuse nicht gedämmt werden. Soll die Einbaulage geändert werden, so muss das Motorgehäuse wie folgt gedreht werden:...
  • Seite 25 Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Einbaumaße Artikel HE OEM 4 XX-15 S 99 mm 130 mm 93 mm 126 mm HE OEM 4 XX-25 S HE OEM 4 XX-25 99 mm 180 mm 94 mm...
  • Seite 26: Elektrischer Anschluss

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 13 Elektrischer Anschluss Schließen Sie das Netzkabel wie dargestellt an die Pumpe an. Vorsicht! Netzspannung! Unbedingt die erforderlichen Schutzmaßnahmen, VDE-Vorschriften und örtlichen Bestimmungen beachten. Der Leiterquerschnitt darf nicht kleiner als 0,75 mm2 sein. Bei Verwendung von feindrahtigen Leitungen sind Aderendhülsen zu benutzen.
  • Seite 27: Wartung Und Service

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 14 Wartung und Service Vor Wartungs-, Reinigungs- und Reparaturarbeiten Anlage spannungsfrei schalten und gegen unbefugtes Wiedereinschalten sichern. Bei hohen Wassertemperaturen und Systemdrücken Pumpe vorher abkühlen lassen. Es besteht Verbrühungsgefahr! 15 Störungen, Ursachen und Beseitigungen...
  • Seite 28 Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Fehlerbild oder Mögliche Ursache Abhilfe Codeanzeige der Pumpe Pumpe spannungsfrei schalten und gegen Rotorblockierung Wiedereinschalten sichern. Wenn möglich Absperrventil vor und hinter der Pumpe schließen oder Wasser ablassen. Je nach Betriebszustand der Anlage kann heißes Wasser austreten ! Verbrennungsgefahr ! Motorkopf durch Lösen der 4 Innensechskant-...
  • Seite 29: Entsorgung

    Betriebsanleitung WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 16 Entsorgung Hinweis Die Pumpe sowie deren Einzelteile gehören nicht in den Hausmüll, sondern müssen umweltgerecht entsorgt werden! Nehmen Sie hierfür bitte die öffentlichen oder privaten Entsorgungsgesellschaften in Anspruch. Im Downloadbereich unserer Homepage befindet sich eine Auflistung der in unseren Produkten verwendeten...
  • Seite 30 Intended use ..........................36 Product data HE OEM 4 | 40-XX I 60-XX I 80-XX ..............37 5.1 Technical data WITA HE OEM 4 | 40-XX I 60-XX I 80-XX ............37 5.2 Delivery range ............................38 Pump description ........................39 Pump settings ..........................
  • Seite 31: Eu Declaration Of Conformity

    Manual WITA HE OEM 4 | 40-XX I 60-XX I 80-XX EU Declaration of Conformity Name of the issuer: Wita Sp. z o.o. Display HE Pumpen Zielonka, ul. Biznesowa 22 86-005 Białe Błota Subject of the declaration: Heating circulation pump...
  • Seite 32: Safety Instructions

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 2 Safety instructions 2.1 General These operating instructions are part of the product and contain basic information that must be observed during assembly, operation and maintenance. For this reason it must be read by the installer and the responsible qualified personnel...
  • Seite 33: Personnel Qualification

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX This symbol indicates useful information Note on handling the product. They draw attention to possible difficulties and are intended to ensure safe operation. Notes attached directly to the product, such as: •...
  • Seite 34: Dangers, If The Safety Instructions Are Not Observed

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 2.4 Dangers, if the safety instructions are not observed Failure to observe the safety instructions may endanger persons, the environment and the system. Failure to comply with the safety instructions will result in the loss of any claims for damages.
  • Seite 35: Safety Instructions For Assembly And Maintenance Works

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX • If hazards should occur in the system due to hot or cold parts, these must be provided with a touch guard. • Highly flammable substances must be kept away from the product.
  • Seite 36: Inadmissible Operating Modes

    4 Intended use The WITA HE OEM high-efficiency pumps are designed for circulating hot water in central heating systems and are also suitable for pumping low-viscosity media in the industrial and commercial sector. They also can be used in solar technology systems.
  • Seite 37: Product Data He Oem 4 | 40-Xx I 60-Xx I 80-Xx

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 5 Product data Technical data HE OEM 4 | 40-XX I 60-XX Characteristic HE OEM 4 | 40-XX Characteristic HE OEM 4 | 60-XX...
  • Seite 38: Delivery Range

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX WITA HE OEM 4 | 80-XX Characteristic HE OEM 4 | 80-XX 3,5 Qm 80-XX Maximum delivery head 8.0 m Maximum flow rate 4000 l/h...
  • Seite 39: Pump Description

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 6 Pump descritption In an average household, 10 to 20% of electricity consumption is caused by conventional stan- dard pumps. With the HE OEM 4 pump series, we have developed a circulation pump with an energy efficiency index ≤...
  • Seite 40: Selection Of The Operating Mode And Operating Level

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Selection of the operating mode and operating level 1. Constant speed mode I, II and III In this operating mode, the pump rotates at a constant speed over the entire characteristic curve.
  • Seite 41 Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX On delivery, the pump ist set to the AUTO Smart Adapt operating level. By repeatedly briefly pressing of the selection button, the operating modes: constant speed, constant pressure, proportional pressure and AUTO Smart Adapt are switched through continously.
  • Seite 42: Recommendations For The Selection Of The Operating Level

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 7.4 Recommendations for the selection of the operating level Optimum Other possible setting settings Underfloor heating Auto 2-pipe heating systems Auto 1-pipe heating system...
  • Seite 43: Optional Special Pwm Function

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 8 Optional special PWM function Optional special function PWM input This function allows the control ot the rotational speed of the pump by an external controller.
  • Seite 44 Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX The maximum cable length is 3m. The signal line is galvanically separated from the pump electronics by an optocoupler. The PWM connection cable must be designed for operation at a nominal operating voltage of 230 VAC.
  • Seite 45 Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX The PWM control signal is a digital signal in which the speed information is contained in the pulse width. The control signal must meet the following requirements:...
  • Seite 46 Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Rise time Fall time...
  • Seite 47: Heating Characteristics

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Heating characteristic In the range between 0 and 5% of the PWM signal, the pump operates at maximum rotational speed for safety reasons. In the case of a fault in the PWM control unit or a cable break, this ensures that the heat Display HE Pumpen produced by the heat generator is transferred.
  • Seite 48: Pwm Feedback Signal (Volumetric Flow)

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX PWM feedback signal (volumetric flow) The PWM feedback signal makes it possible to transmit information about the operating status of the pump to an external control system. It contains information on the current volumetric flow and on fault conditions of the pump.
  • Seite 49 Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Overview of the definition of the output signals Type Description Definition PWM cable is not connected or pump No PWM signal is disconnected from the power supply.
  • Seite 50: Filling And Venting The System

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 9 Filling and venting the system The system must be filled and vented properly. To vent the pump, the electronics Advice should be set to level III and the pump should be operated in this position for at least 20 minutes.
  • Seite 51: Relation Between Pump Settings And Performance

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 10 Relation between pump settings and performance The characteristics show the relation between pump settings and performance. AUTO AUTO 11 Performance characteristics HE OEM 4 | 40-XX...
  • Seite 52: Assembly

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 12 Assembly Correct assembly position of the motor A voltage-free assembly must be carried out with the pump motor in a horizontal position (the direction arrow on the pump body indicates the flow direction).
  • Seite 53 Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Assembly dimensions Article HE OEM 4 XX-15 S 99 mm 130 mm 93 mm 126 mm HE OEM 4 XX-25 S HE OEM 4 XX-25...
  • Seite 54: Electrical Connection

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 13 Electrical connection Connect the mains cable to the pump as shown in the figure. Caution! Mains voltage! Always observe the necessary safety measures, VDE regulations and local regulations.
  • Seite 55: Maintenance And Service

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 14 Maintenance and service Before carrying out maintenance, cleaning and repair works, disconnect the system from the power supply and secure it against being switched on again by unauthorized persons.
  • Seite 56 Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Error pattern or pump Possible cause Remedy error code Rotor block Disconnect the pump from the power supply and secure it against being switched on again.
  • Seite 57: Disposal

    Translation of the original operating instructions WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 16 Disposal Advice The pump and its individual parts does not belong in household waste, but must be disposed of in an environmentally friendly manner! Please use the services of public or private waste management companies for this purpose.
  • Seite 58 Transport i magazynowanie ......................64 Użytkowanie zgodne z przeznaczeniem ..................64 Informacje o produkcie ......................65 5.1 Dane techniczne WITA HE OEM 4 | 40-XX I 60-XX I 80-XX ............65 5.2 Zakres dostawy ............................66 Opis pompy ..........................67 Ustawienia pompy a natężenie przepływu ................67 7.1 Przycisk...
  • Seite 59: Deklaracja Zgodności Ue

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX DEKLARACJA ZGODNOŚCI UE Producent: Wita Sp. z o.o. Display HE Pumpen Zielonka, ul. Biznesowa 22 86-005 Białe Błota Wyrób: Pompa centralnego ogrzewania Typ: WITA HE OEM 4...
  • Seite 60: Wskazówki Bezpieczeństwa

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 2 Wskazówki bezpieczeństwa 2.1 Informacje ogólne Niniejsza instrukcja obsługi stanowi integralną część produktu i zawiera podstawowe informacje, które należy brać pod uwagę podczas montażu, użytkowania i konserwacji urządzenia.
  • Seite 61: Kwalifikacje Personelu

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Tutaj zawarte są przydatne wskazówki Wskazówka dotyczące użytkowania produktu. Wskazują one na możliwość wystąpienia trudności, mają na celu zapewnienie bezpiecznej pracy. Wskazówki umieszczone bezpośrednio na produkcie, takie jak: •...
  • Seite 62: Zagrożenia W Przypadku Nieprzestrzegania Wskazówek Bezpieczeństwa

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 2.4 Zagrożenia w przypadku nieprzestrzegania wskazówek bezpieczeństwa Nieprzestrzeganie wskazówek bezpieczeństwa może spowodować zagrożenie dla ludzi i środowiska oraz skutkować uszkodzeniem instalacji. Nieprzestrzeganie wskazówek bezpieczeństwa spowoduje utratę wszelkich roszczeń...
  • Seite 63: Wskazówki Bezpieczeństwa Dotyczące Montażu I Prac Konserwacyjnych

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX • Należy wyeliminować zagrożenia związane ze skutkami działania energii elektrycznej. W tym celu należy przestrzegać przepisów i zasad ochrony przeciwporażeniowej oraz wytycznych SEP i lokalnych dostawców energii.
  • Seite 64: Niewłaściwa Obsługa

    4 Użytkowanie zgodne z przeznaczeniem Energooszczędne pompy WITA HE OEM 4 są skonstruowane w celu wspomagania przepływu ciepłej wody w instalacjach centralnego ogrzewania, nadają się również do tłoczenia rozrzedzonych mediów w przemyśle i rzemiośle. Mogą być rownież...
  • Seite 65: Informacje O Produkcie

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 5 Informacje o produkcie Dane techniczne WITA HE OEM 4 40-XX I 60-XX Charakterystyka HE OEM 4 | 40-XX Charakterystyka HE OEM 4 | 60-XX 40-XX 60-XX Maksymalna wysokość...
  • Seite 66: Zakres Dostawy

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Dane techniczne HE OEM 4 I 80-XX Charakterystyka HE OEM 4 | 80-XX 3,5 Qm 80-XX Maksymalna wysokość podnoszenia 8,0 m Maksymalne natężenie przepływu 4000 l/h Pobór mocy P1 (W)
  • Seite 67: Opis Pompy

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 6 Opis pompy W przeciętnym gospodarstwie domowym od 10 do 20% zużycia energii elektrycznej przypada na pompy tradycyjne. Wraz z serią pomp HE OEM 4 stworzyliśmy pompę cyrkulacyjną o współczyn- niku efektywności energetycznej ≤...
  • Seite 68: Wybór Trybu I Poziomu Pracy

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Wybór trybu i poziomu pracy 1. Tryb stałej prędkości obrotowej I, II i III W tym trybie pracy pompa obraca się ze stałą prędkością w całym zakresie charakterystyki.
  • Seite 69 Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Pompa jest ustawiona fabrycznie w trybie AUTO Smart Adapt. Wielokrotne krótkie naciśnięcie przycisku wyboru powoduje ciągłe przełączanie pomiędzy poszczególnymi trybami pracy: stałą prędkością obrotową, stałym ciśnieniem, proporcjonalnym ciśnieniem i AUTO Smart Adapt.
  • Seite 70: Zalecenia Dotyczące Wyboru Poziomu Pracy

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 7.4 Zalecenia dotyczące wyboru poziomu pracy Optymalne Inne możliwe ustawienie ustawienia Ogrzewanie podłogowe AUTO 2-rurowe systemy grzewcze AUTO 1-rurowy system grzewczy Ustawienie fabryczne = AUTO Smart Adapt...
  • Seite 71: Opcjonalna Funkcja Specjalna Pwm

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 8 Opcjonalna funkcja specjalna PWM Opcjonalna funkcja specjalna - wejście PWM Funkcja ta umożliwia sterowanie prędkością obrotową pompy za pomocą regulatora Display HE Pumpen zewnętrznego. Aby można było korzystać z tej funkcji, pompa musi być wyposażona w odpowiednie wejście.
  • Seite 72 Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Maksymalna długość przewodu wynosi 3m. Linia sygnałowa jest galwanicznie oddzielona od elektroniki pompy za pomocą transoptora. Przewód przyłączeniowy PWM musi być przystosowany do pracy przy minimalnym napięciu roboczym 230 VAC.
  • Seite 73 Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Sygnał sterujący PWM jest sygnałem cyfrowym, w którym informacja o prędkości jest zawarta w szerokości impulsu. Sygnał sterujący musi spełniać następujące wymagania: Przykład syngału PWM o wartości 40%:...
  • Seite 74 Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Czas narastania Czas opadania...
  • Seite 75: Charakterystyka Ogrzewania

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Charakterystyka ogrzewania W zakresie od 0 do 5% wartości sygnału PWM pompa pracuje z maksymalną prędkością obrotową ze względów bezpieczeństwa. Zapewnia to przepływ ciepła wytworzonego przez generator w przypadku awarii sterownika Display HE Pumpen PWM lub przerwania kabla.
  • Seite 76: Sygnał Zwrotny Pwm (Objętościowe Natężenie Przepływu)

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Sygnał zwrotny (przepływ objętościowy) Sygnał zwrotny PWM umożliwia przekazywanie informacji o stanie pracy pompy do zewnętrznego sterownika. Zawiera informacje o bieżącym przepływie objętościowym oraz o trybach awaryjnych pompy. Sygnał wyjściowy posiada stałą częstotliwość 75Hz i jest galwanicznie odizolowany od pozostałych układów elektronicznych pompy.
  • Seite 77 Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Przegląd definicji sygnałów wyjściowych Opis Definicja Niepodłączony kabel PWM lub pompa Brak sygnału PWM odłączona od sieci. Pompa jest zatrzymywana przez Zatrzymanie pompy sygnał PWM Pompa pracuje prawidłowo,...
  • Seite 78: Napełnianie I Odpowietrzanie Instalacji

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 9 Napełnianie i odpowietrzanie instalacji Należy prawidłowo napełnić i odpowietrzyć instalację. Aby odpowietrzyć Uwaga pompę, należy ustawić układ elektroniczny na poziomie III, pompa powinna pracować w tej konfiguracji przez co najmniej 20 minut. Po zakończeniu tego procesu można ustawić...
  • Seite 79: Zależność Między Ustawieniami Pompy A Jej Wydajnością

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 10 Zależność między ustawieniami pompy a jej wydajnością Zależność pomiędzy ustawieniami pompy a jej wydajnością przedstawiają krzywe charakterystyk. AUTO AUTO 11 Charakterystyki wydajności HE OEM 4 | 40-XX...
  • Seite 80: Montaż

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 12 Montaż Prawidłowe położenie montażowe silnika Silnik pompy należy montować w pozycji poziomej, po odłączeniu zasilania (strzałka kierun- kowa na korpusie pompy wskazuje kierunek przepływu). Podczas wykonywania prac termoizo- lacyjnych należy zwrócić...
  • Seite 81 Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Wymiary montażowe Artykuł HE OEM 4 XX-15 S 99 mm 130 mm 93 mm 126 mm HE OEM 4 XX-25 S HE OEM 4 XX-25 99 mm...
  • Seite 82: Przyłącze Elektryczne

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 13 Przyłącze elektryczne Podłącz kabel zasilający do pompy w sposób przedstawiony na rysunku. Uwaga! Napięcie sieciowe! Należy bezwzględnie przestrzegać niezbędnych środków bezpieczeństwa, przepisów SEP oraz wytycznych lokalnych dostawców energii.
  • Seite 83: Konserwacja I Serwis

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 14 Konserwacja i serwis Przed przystąpieniem do prac konserwacyjnych, czyszczenia i napraw należy odłączyć instalację od zasilania i zabezpieczyć ją przed ponownym włączeniem przez osoby nieupoważnione.
  • Seite 84 Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX Schemat błędu Możliwa przyczyna Działania zaradcze Blokada wirnika Odłączyć pompę od zasilania i zabezpieczyć ją przed ponownym włączeniem. Jeżeli to możliwe, należy zamknąć zawór odcinający przed i za pompą, lub spuścić...
  • Seite 85: Utylizacja

    Tłumaczenie oryginalnej instrukcji obsługi WITA HE OEM 4 | 40-XX I 60-XX I 80-XX 16 Utylizacja Uwaga Pompy ani jej poszczególnych części nie należy wyrzucać do odpadów domowych, lecz utylizować w sposób przyjazny dla środowiska! W tym celu należy skorzystać...
  • Seite 86 Notatki...
  • Seite 87 Notatki Display HE Pumpen...
  • Seite 88 WITA - Wilhelm Taake GmbH WITA Sp. z o.o. Böllingshöfen 85 | D-32549 Bad Oeynhausen Zielonka, ul. Biznesowa 22 | 86-005 Białe Błota Tel.: +49 5734 512380 | Fax: +49 5734 1752 Tel.: + 52 564 09 00 | Fax: + 52 564 09 22 www.wita.de | info@wita.de...

Diese Anleitung auch für:

He oem 4 60-serieHe oem 4 80-serie

Inhaltsverzeichnis