SPECIFICATION:
Power Sourcing: 230V
Power Frequency: 50Hz
Ambient Light: <3-2000LUX (adjustable)
Time-Delay: min: 10sec±3sec
Max: 12min±1min
Rated Load: 1200W (incandescent lamp)
300W (energy-saving lamp)
FUNCTION:
Can identify day and night: It can work in the daytime and at
night when it is adjusted on the "sun" position (max). It can
work in the ambient light less than 3LUX when it is adjusted
on the "moon" position (min). As for the adjustment pattern,
please refer to the testing pattern.
SENS adjustable: It can be adjusted according to using
location. The detection distance of low sensitivity could be
only 1m (radius) and high sensitivity could be 8m (radius)
which fits for large room.
Time-Delay is added continually: When it receives the second
induction signals within the first induction period, it will
compute time once more on the basic of the first time-delay
rest.
Time–Delay is adjustable. It can be set according to the consumer's desire. The minimum
time is 10sec±3sec. The maximum is 12min±1min.
NOTE: the high-frequency output of this
sensor is <0.2Mw- that is just one 100
transmission power of a mobile phone or the
output of a microwave oven.
INSTALLATIION: (see the diagram)
Switch off the power.
Please move the upper cover with anti-clockwise whirl as per the diagram in the crust.
Screw off the middle cover; fix the bottom on the selected position with the inflated screw.
Connecting the power and the load to sensor as per the connection-wire sketch diagram.
Then screw on the middle cover.
Detection Range: 360°
Detection Distance: 1-8m (radius) adjustable
HF System: 5.8GHz CW radar, ISM band
Transmission Power: <0.2mW
Installing Height: 1.5-3.5m
Power Consumption: approx 0.9W
Detection Motion Speed: 0.6-1.5m/s
th
of the
Buttoning the upper cover on the sensor, whirling the cover with clockwise. Then you could
switch on the power and test it.
CONNECTION-WIER SKETCH DIAGRAM
TEST:
Turn the LUX knob clockwise on the maximum.
Turn the TIME knob anti-clockwise on the
minimum, Turn the SENS knob clockwise on the
max.
When you switch on the power, the light will be on at once. And 6sec±2sec later the light
will be off automatically. Then if the sensor receives induction signal again, it can work
normally.
When the sensor receives the second induction signals within the first induction period, it
will compute time once more on the basic of the first time-delay rest.
Turn LUX knob anti-clockwise on the minimum. If the ambient light is less than 3LUX, the
inductor load could work when it receives induction signal
Note: when testing in daylight, please turn LUX knob to
the sensor lamp could not work!
NOTES
Electrician or experienced human can install it.
Can not be installed on the uneven and shaky surface
In front of the sensor there shouldn't be obstructive object affecting detection.
Avoid installing it near the metal and glass which may affect the sensor.
For your safety, please don't open the case if you find hitch after installation.
In order to avoid the unexpected damage of product, please add a safe device of current 6A
when installing microwave sensor, for example, fuse, safe tube etc.
(SUN) position, otherwise