Intended use
- Chain drive for electric opening and closing of
windows and flaps
- Useable for daily natural ventilation
- Operating voltage 24 VDC
- Suitable for indoor mounting only

Safety notes

Operating voltage 24 VDC!
Do not connect directly to the mains supply!
- Connection must be carried out by a certified
electrical technician
- Danger of crushing hands and fingers!
- Keep people away from the operating area of the drive
- Keep children away from the control
- Use only in dry rooms
- Suitable for indoor mounting only
Use rain detector in locations if there is a risk of rain
- Use unmodified original D+H parts only
- Observe the bracket-set mounting instructions
Observe enclosed red safety note!

Scope of supply

Drive unit with 2.5 m PVC cable. Depending on the
type of window, different bracket sets are available
separately.

Technical data

Type
Rated voltage
Performance
Holding force
Nominal pressure
Nominal tractive force
Service life
Duty cycle
Housing
Protective system
Temp.range
Nominal stroke length:
VCD 22/15
VCD 22/25
VCD 22/35
4/12
VCD 22
VCD 22
24 VDC / ±20% / 0,35 A
10 VA
approx. 1500 N (Excluding bracket)
200 N + approx. 20% cut-off reserve (Temporary)
150 N (Safety cut-off force)
>10 000 double strokes
30 % (With cycle time 10 minutes)
Z
inc-diecasting, RAL 9006 (White aluminium)
IP 50
0 ... +60°C
150 mm
250 mm
350 mm
English
Features
-
C
onnection via plug connector
-
T
andem-safety function for operation of 2 drives
on one sash
TMS function
Whenever two drives are operated on a single
sash,the tandem safety function (TMS) can be
used.This function connects the cut-offs of the two
drives in such a way that if one drive is cut off due to
overload, the other drive will similarly be cut off.
99.820.93 4.0/03/12