indoor unit from side to side to see that it is securely hooked.
3.
The female half can be easily past through by lifting the indoor unit with a cushioning material bet-
ween the indoor unit and the wall. Get it out after finishing it.
4.
Push the lower part of the indoor unit up on the wall. Then move the indoor unit from side to side, up
and down to check if it is hooked securely.
Indoor unit
Connective cable
Drain hose
Fig. 9
See picture 11:
Bending the refrigerant piping at the back of the unit needs to be done with the highest care! The piping con-
sists out of cupper. When bending the highlighted part more than 1 time the Cupper will start cracking due
to a physical process. Cracking can cause leakage refrigerant leakage and is not covered by the warranty.
Do not bend!
Bend
(Only 1 x)
5. Piping and wrapping
Bundle the tubing, connecting cable, and drain hose with tape securely, evenly as shown in Fig.9.
ATTENTION
• Because the condensed water from rear of the indoor unit is gathered in ponding box and is
piped out of room. Do not put anything else in the box.
• Connect the indoor unit first, then the outdoor unit.
4
74
Ponding box
Pipe room
Connective pipe
Wrapping belt
Fig. 10
Bend
(Only 1 x)
Fig. 11
Indoor unit outline