Technical data
LoRaWAN® radio interface
Operating frequency
Max. transmission power
Duration of transmission telegrams
Transmission interval
Data transmission procedure
Encoding of radio protocols
Error detection
Battery status monitoring
CE conformity
Activation of the radio interface
LoRaWAN® radio telegram
Protocol content
Equipment number
Device-specific information
(firmware version, LoRaWAN® version, device type)
Due date value and date [01.01.]
Changes of status
(manipulation, battery warning, ...)
Scenario 201 (monthly)
Protocol content
Monthly value (previous month) [litres], status
information, actual date and time
Monthly value (previous month) [litres], mid-month value
[litres], actual date and time
Scenario 202 (daily)
Protocol content
Daily values (previous day) [litres]
Status information, actual date and time
Other scenarios on request.
868 MHz
approx. 14 dBm, 25 mW
up to 1.5 s (depending on spreading factor)
depending on the respective meter configuration, e.g. every day;
optional: monthly or 8 telegrams with three hourly values each
LoRaWAN® class A (bi-directional communication)
yes
CRC
yes
according to directive 2014/53/EU (RED)
• automatically after the meter has been filled with water;
• via the NFC interface using the related ZENNER NFC Coupler,
MinoConnectUSB and MSS configuration software
• via the NFC interface using the Android app ZENNER Device Manager Basic
Interval
once when logging into the LoRaWAN® network
six-monthly
every year on due date
event-driven
Interval
monthly (beginning)
monthly (middle)
Interval
daily
monthly
11