Operation:
1.
Switch the thermostat on or off
Press the ▲ or ▼ button in the weekly programme mode to activate the temporary control.
2.
Use the UP ▲ or DOWN ▼ buttons to set the temperature value.
3.
4.
Press the button
with the ▲ / ▼ keys. Press
5.
Press the button
6.
In the weekly programme mode, the SET temperature and time are shown alternately at the bottom of the display. The ACTUAL room temperature
can be read directly from the centre of the display.
To activate or deactivate the key lock, press the ▲ and ▼ key simultaneously for 5 seconds. When the key lock is active, the
7.
the display.
Advanced settings:
To access the advanced settings, first switch off the unit (OFF appears in the display).
Then press the
and
key at the same time.
1ADJ: Calibration temperature sensor.
Press the ▲ or ▼ key to set the value.
Adjustable between -9.9 and +9.9°C. Standard 0.0°C.
Press the Menu key for the next step.
2SEN: Selection of the sensor mode.
Press the ▲ or ▼ key to set the value.
IN: internal sensor
OUT: floor sensor
ALL: both sensors, floor sensor is the limit sensor
Press the Menu key for the next step.
3LIT: Setting the temperature limit
Press the ▲ or ▼ key to set the value.
Adjustable between +5 and +60°C. Standard 0.0°C.
Press the Menu key for the next step.
4DIF: Setting the hysteresis
Press the ▲ or ▼ key to set the value.
Adjustable between +0.5 and +10°C. Standard 1.0°C.
Press the Menu key for the next step.
5LTP: Frost protection
Press the ▲ or ▼ key to set the value (OFF/ON).
Press the Menu button for the next step.
for 5 seconds to set the day and time. Set the minutes with the ▲ / ▼ keys, pressing the
to set the current day (1-7 / Mon.-Sun.) with the ▲ / ▼ keys and press again
, to select the mode (manual / weekly programme).
to reach the hour setting, set it
to save the setting.
6PRG: Set day/grouping for weekly programming.
Press the ▲ or ▼ key to set the value.
Mode 5/2-days (Mon.-Fri. + Sa.-Sun.)
Mode 6/1 days (Mon.-Sun. + Sun.)
Mode 7 days (Mon.-Sun.)
Mode OFF (no weekly programme)
Press the Menu key for the next step.
7RLE: Function not available on this model.
Press the Menu button for the next step.
8DLY: Function not available on this model.
Press the Menu button for the next step.
9HIT: Setting the max. Temperature
Press the ▲ or ▼ key to set the value.
Adjustable between +35 and +90°C. Standard 50°C.
Press the Menu button for the next step.
AFAC: Reset to factory setting
Press the ▲ key until --- appears in the display.
Then press the
button.
-symbol appears in