Technical data:
Voltage
Max. Switching capacity
Power consumption
Temperature setting range
IP protection
Temperature limit
Hysteresis
Ambient temperature range
Bodensensor R25°C
Programming:
Press the Menu button for 5 seconds to start programming.
Assembly steps:
1. Loosen the front cover by inserting a screwdriver into the lower slot.
3. Secure the mounting plate in the wall mounting box/cavity wall box using
a screwdriver.
230 VAC, 50-60 Hz
16A
2 W
+5 to +90°C
IP20
+5 to +60°C (Standard: 35°C)
0.5-10°C (Standard 1.0°C)
-5 ~ 50°C
10kOhm
Circuit diagram:
Note:
1)
The pre-programmed setpoint (15°C) for event 3&4 is the same
as for event 2, please adjust it according to your individual
requirements.
2)
The "OFF" symbol is displayed when the setpoint reaches the
minimum setting value and the thermostat is switched off in this
event.
Dimensions (mm):
2. Dismantle the mounting plate according to the following diagram.
4. After connecting the wires (see circuit diagram), the thermostat is mounted
on the mounting plate and the frame is put back on.