Viewing other information about the active
cycle:
Check that the keypad is not locked.
1. Touch the DOWN key to view the type of active
cycle.
Label
LED
Time controlled blast chilling
PoS
and conservation
Time controlled blast freezing
nEG
and conservation
2. Touch the DOWN key again to view the cabinet
temperature.
3. Touch the SET key (or take no action for 15 s)
to exit the procedure.
After a power failure during a cycle, the cycle is
automatically reactivated from the phase it was
in at the moment the power failed. If power fails
during blast chilling/freezing, the count is resumed
with a maximum error of 10 minutes.
Activating temperature controlled
blast chilling/freezing and
conservation
Check that the keypad is not locked and that
defrosting is not active.
1. Touch the SET key to select a cycle.
Label
LED
Temperature controlled blast
PoS
chilling and conservation (if
E0 = 0 or 1)
Temperature controlled blast
nEG
freezing and conservation (if
E0 = 1 or 2)
2. Touch the DOWN key within 15 s to view
the product temperature at the end of blast
chilling/freezing.
3. Touch the SET key.
20
CK640_ML_A5_v5_20221025.indb 20
CK640_ML_A5_v5_20221025.indb 20
4. Touch the UP or DOWN key within 15 s to set
5. Touch the SET key (or take no action for 15 s).
6. Touch the DOWN key within 15 s to view the
7. Touch the SET key.
8. Touch the UP or DOWN key within 15 s to set
Description
9. Touch the DOWN key within 15 s to view the
10. Touch the SET key.
11. Touch the UP or DOWN key within 15 s to set
12. Touch the SET key (or take no action for 15 s).
13. Touch the DOWN key within 15 s to view the
14. Touch the SET key.
15. Touch the UP or DOWN key within 15 s to set
16. Touch the SET key (or take no action for 15 s).
17. Touch the START/STOP key within 15 s.
The settings are temporary. When a new cycle is
activated (and after a power failure), the device
will restore the r3/r4, r5/r6, r7/r8 and r9/rA values.
If the temperature of the needle does not reach
the product temperature at the end of blast
chilling/freezing within the maximum duration
of blast chilling/freezing, the cycle fails but the
temperature will keep pulling down until it reaches
the setting temperature.
Information about the active cycle:
Description
the value.
maximum duration of blast chilling/freezing.
the value.
cabinet setpoint during blast chilling/freezing.
the value.
cabinet setpoint during conservation.
the value.
Phase
Information displayed
Blast chilling/freezing
Needle temperature
active
End blast chilling/
End (press a key)
freezing
Conservation active
Cabinet temperature