Herunterladen Inhalt Inhalt Diese Seite drucken

Reset To Factory Settings; Technical Specifications - urmet VOG5 1760/6 Installationsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 18
5.
HOW TO ACCESS PROGRAMMING MODE
To enter device programming mode, press and hold the
seconds) while the device is in stand-by.
Access to the programming mode is confirmed by three short beeps and by the visual indication of the
key LED, which starts flashing in orange.
The programming mode can be exited by pressing the
confirmed by 2 long beeps and by the LED on the
status (see chapter "LED status signalling").
The device automatically closes programming mode after 10 minutes from access.
6.
INTERCOM DESTINATION ADDRESS ACQUISITION
To acquire an intercom address, the user must proceed as follows:
Enter programming mode.
Press and hold down the key to be programmed (approx. 3 seconds) (
device beeps for a short time.
The device is then set for intercom call.
Go to the video door phone (B) to be called from that button and press
Or, alternatively, go to a calling station and press the call button of the user associated with the video
door phone (B).
For further information, follow the instructions in the system manual.
7.

RESET TO FACTORY SETTINGS

To restore default parameters of the device after entering programming mode, hold button
longer than 5 seconds, press the
will emit 2 long beeps to confirm and exit the programming state.
8.

TECHNICAL SPECIFICATIONS

Power voltage: ................................................................................................................................36 ÷ 48 V
Maximum consumption: .................................................................................................................... @ 48 V
Stand-by: .......................................................................................................................................... < 3 mA
Full rate:: .................................................................................................................................. < 160 mAcc
Terminals S+ and S- output .................................................................................................... 25 mA @ 24V
Display ..........................................................................................................................................5'' TFT-LCD
Display resolution ....................................................................................................................800 X 480 pixel
Operating temperature range: ......................................................................................................... -5° ÷ 50°C
Dimensions (LxDxH): ........................................................................................................ 160 x 130 x 26 mm
15.105 Information to the user statements:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
DS1760-001
button for an extended period (more than 5
key for a long time. The operation will then be
key which will stop flashing, returning to its previous
and
buttons together for longer than 3 seconds. The system
1
2
3
or
or
) until the
to confirm the acquisition.
pressed for
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis