OPERATION
Dry vacuuming
Note: Only vacuum using the dust bag.
1. Mount the hose on the suction connection and select the desired suction nozzle.
2. Plug the power cord into a proper outlet. (See safety instructions)
3. Switch on the multi-purpose vacuum cleaner by setting the toggle switch to the On position „I".
4. After the suction process, switch the appliance off again by setting the toggle
switch to the Off „0" position.
5. Unfold the dust bag and press it against the inside of the suction port.
It should snap into place and be firmly seated. To empty the dust bag, slide the rail down from
the end of the bag and empty the bag.
6. To seal, slide the rail onto the end of the bag.
Wet Suction
Note: Remove the dust bag before vacuuming liquids. Check the operation of the safety float valve.
Attention: In case of foam development or liquid leakage, stop work immediately and empty the dirt
container!
If the vacuuming stops and the float has risen up when the liquid is sucked out even though the
collection tank is not full, please stop your vacuum cleaner and wait for a while. The water from the
float will flow down and the float will return to its normal position. If your vacuum cleaner tips over
during liquid suction, the float will close the suction hole and stop suctioning. Place the multi-purpose
vacuum cleaner in the upright position and wait until the float has sunk down to continue vacuuming.
Blow function
The vacuum has a blowing function for blowing out inaccessible places or for drying the surfaces of
damp objects.
1. Mount the hose on the blow port and select the desired nozzle.
2. Insert the power plug into a proper power outlet. (S. Safety note, point 2)
3. Switch on the multi-purpose vacuum cleaner by setting the toggle switch to the On position „I".
4. After the blowing process, switch the unit off again by setting the toggle switch to the Off „0"
position.
Attention: Do not discharge the blown air into rooms in an uncontrolled manner.
Always use a clean hose when using the blowing function. Whirled-up dust can be hazardous to health.
Do not use the blowing function in confined spaces.
16
Item Number: 3144
OPERATION
Emptying the collecting vessel
1. Switch off the multi-purpose vacuum cleaner and disconnect the appliance from the mains socket.
2. Open the locking hooks on both sides of the collection tray and pull the handle to remove the top.
3. Remove the dust bag and empty it.
4. Empty the dust container if necessary.
5. Replace the filter bag.
6. Put the upper part back on the housing and close the locking hooks.
Cleaning
• Warning! Always disconnect the appliance from the mains before cleaning.
• Clean the device with a damp cloth and wipe it dry immediately. Do not use abrasive or chemical
cleaners to clean the unit.

TECHNICAL DATA

Operating voltage: 220-240V ~ 50/60Hz
Power 2800W
Suction power: 21,5 kPa
Protection class: II
Protection class: IPX4
Capacity dust bag: 2 litres
Water suction capacity: Max. 2.5 litres
DISPOSAL
Dispose of packaging material in an environmentally friendly manner and take it to the
collection of recyclable materials.
This appliance is subject to the European Directive 2012/19/EU on Waste Electrical and
Electronic Equipment (WEEE). Do not dispose of this appliance as normal household waste,
but in an environmentally friendly manner via an officially authorised disposal company.