Before use

The remote control is supplied with 2 x AAA batteries, which must be inserted before use.
Furthermore, the remote control and the MotorController must be paired with each other before the remote control can operate the
actuators connected to the MotorController.

11.1.1 Pairing of remote control and MotorController

To avoid any disturbances the remote control must be held close to the MotorController during pairing. Only activate pairing mode
on one MotorController at the time, otherwise, the remote control will pair with the MotorController with the strongest Bluetooth
signal.
A remote control can only be paired with one MotorController.
MotorController
1.
Activate pairing mode on MotorControlleren by pressing K5 (Bluetooth pairing button) on the MotorControlleren.
Remote control
The remote control differs between two different presses; a short and a long press.
The short press is used for normal/daily operation, meaning control of the window actuators. The long press is used for the pairing
process.
Short press: the press lasts max. 3 sec.
Long press: the press lasts min. 3 sec.
Activate pairing mode on the remote control, by pressing simultaneously on key #3 and #9 – see above "Button and key
1.
function overview". The press must be a long press on both keys meaning min. 3 sec.
When the remote control is in pairing mode it starts blinking first red and then green double blinks.
2.
As the remote control only can be paired with one MotorController, the remote control automatically deletes any previously
paired MotorControllers before it starts the pairing process with the desired MotorController.
3.
The remote control starts a scanning process to identify the desired MotorController, which also must be the one closest to
the remote control.
On the remote control, the scanning is indicated by the green LED, which every second blinks two short blinks.
4.
a) The LED on the remote control blinks one long green blink. The pairing process was a success, the remote control and
the MotorController is now paired.
b) The LED on the remote control blinks one long red blink. The pairing process failed.
The pairing process succeeded:
The MotorController and remote control are now ready for use. Carry out a test run, if this is the MotorController's first pairing,
see chapter "Commissioning and test run".
The pairing process failed:
-
Ensure that the batteries are inserted correctly into the remote control.
-
Ensure that the MotorControllere has been connected to 230V and that pairing mode is activated.
Ensure that MotorController and remote control – during the pairing process – are close to each other and that there are
-
no disturbances between them, such as walls, furniture etc.
-
Replace the batteries in the remote control.
-
Repeat the pairing process.
If the pairing process continues to fail please contact your local WindowMaster office.

Control via app

12
The windows can also be controlled via app. The MotorController must be version 02 or higher for the app to be used.
The app "Fresh Air Control" can be downloaded from Google Play or App Store.
The app can connect to several MotorControllers. WindowMaster recommends connecting max. 5 MotorControllers to a
smartphone/tablet and max. 5 smartphones/ tablets to a MotorController.

Status and troubleshooting via LED on the MotorController

13
In the event of failure/error of the MotorController one or more diodes will light and/or blink.
On the WCC 10 6BT there are 4 diodes - 3 green and 1 yellow - that can indicate errors and status on the MotorController.
Irrespective which diode lights or blinks, the indicator is based on a 3.2 second sequence that is repeated continuously. Each
sequence is defined by 32 x 0.1 second time segments.
If there are several errors on the MotorController simultaneously they are displayed by priority, i.e. error messages for the most
critical failures are shown first and repeated until the failure is remedied. Then error number two is shown, which likewise is