Herunterladen Inhalt Inhalt Diese Seite drucken

Remote Control - Window Master WCC 106 BT Installationsanleitung

Motorcontroller
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

DIP
Description on the
switch
MotorControlleren
8
ML 2, motors run
independently

Remote control

11
The WCC 106 BT is supplied with a remote control for controlling (opening and closing) the window actuators, which are connected
to the MotorController.
The remote control has an operation range up to 50m outside and 10m inside.
Physical barriers such as walls, cabinets etc. will reduce the operation range.
Button and key functions on the remote control
#1
#4
#7
#2
#5
#8
#3
#6
#9
Button and key function
overview
ML = motor line
A short blink on the remote control's green LED indicates that the command from the remote control to the MotorController has
been received by the MotorController.
A short blink on the remote control's red LED indicates that the command from the remote control to the MotorController has not
been received by the MotorController.
ON: the actuators on motor line 2 are controlled individually via input X2, X3, X4 and X5.
Up to 4 actuators can be connected to motor line 2 and all actuators must be single / -1
actuators.
The actuator's serial number determines, which input controls which actuator, the serial
number is automatically identified by the firmware in the MotorController.
X2 – controls the actuator with the highest serial number
X3 – controls the actuator with the second-highest serial number
X4 – controls the actuator with the second-lowest serial number
X5 – controls the actuator with the lowest serial number
The actuators can be identified by activating the different inputs.
The serial number can also be read on the product label on the actuator.
Actuators on motor line 1 are controlled together via input X10. Up to 4 actuators can be
connected to motor line 1. All actuators on motor line 1 must be of the same type, incl. team
size and chain length. The actuators must be either single /-1 or quad /-4.
All connected actuators on both motor lines must be MotorLink® actuators and DIP switch #5
must also be set to ON.
This DIP switch setting does not influence how the actuators on the two motor lines are
controlled via the remote control.
(this setting requires MotorLink® actuators and that DIP switch 5 is set to "ON")
OFF: 2 Motor groups with a motor line each
The remote control has 3 buttons, each with 3 keys (functions) –
OPEN, STOP and CLOSE.
Key number
#1
Function
Actuators
connected to
ML #1 open
Key number
#2
Function
Actuators
connected to
ML #2 open
Key number
#3
Function
All actuators
connected to WCC
106 BT open
DIP switch position
#4
Actuators
connected to
ML #1 stop
#5
Actuators
connected to
ML #2 stop
#6
All actuators
connected to WCC
106 BT stop
15
#7
Actuators
connected to
ML #1 close
#8
Actuators
connected to
ML #2 close
#9
All actuators
connected to WCC
106 BT close

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis