Herunterladen Diese Seite drucken
Commend OD5 FBDUR Bedienungsanleitung
Commend OD5 FBDUR Bedienungsanleitung

Commend OD5 FBDUR Bedienungsanleitung

Blindmodule für rfid-lesegeräte für concerto-touch-sprechstellen.
Verfügbare Sprachen

Verfügbare Sprachen

OD5 FBDUR/OD10 FBDUR
Dummy modules for RFID readers for Concerto touch stations.
Mounting
OD5 FBDUR
OD10 FBDUR
NOTE: Brick wall
mounting
For mounting on
brick walls, addition-
ally the flush mount
box OD5 FBSDUR or
OD10  FBSDUR is required
(available separately). In
this case, plaster the flush
mount box into the wall
and continue with
.
 Cut out an opening in the wall using the supplied template as a guide.
 Screw in the locking screw on the OD5 FBDUR clockwise as far as it will go and lift the frame off
towards the locking screw.
 Depending on the cable feed used, break out one of the cable glands.
 Position the mounting box so that the self-locking notch points downwards for the OD5 FBDUR and
to the right for the OD10 FBDUR. Insert the mounting box into the wall. Press the four claw clamps
on the sides of the mounting box outwards and tighten them using the screws (TX 08).
 Attach the RFID reader to the frame or install it in the mounting box. Do not remove the fixing
brackets when attaching the RFID reader to the frame. To install the RFID reader in the mounting
box, remove the fixing brackets and spacer plates, insert the RFID reader and reattach the fixing
brackets on the PCB in parallel with the frame. RFID readers with a PCB thickness between 1.4 mm
and 1.6 mm can be installed in the mounting box.
 Position the frame so that the locking screw points downwards for the OD5 FBDUR and to the right
for the OD10 FBDUR. Place the frame onto the fixing brackets.
 Press the frame firmly against the mounting box and screw the locking screw counterclockwise as
far as it will go. Ensure that the frame is locked in place.
NOTE: Disassembly
To disassemble, screw in the locking screw
clockwise as far as it will go and lift the frame off
towards the locking screw.
Extent of supply
• Dummy module (incl. mounting box)
• Short reference
Dimensions
Measuring units in mm (in), not to scale!
OD5 FBDUR
OD10 FBDUR
146 (5.75)
174 (6.85)
Mounting instructions
• Avoid direct sunlight.
• Install the dummy module with a distance of min. 100 mm (4 in) to walls and other objects to enable
access to the locking screws (TX 08).
• Note the mounting orientation:
• OD5-FBDUR: Locking screw facing down
• OD10-FBDUR: Locking screw facing to the right
• For brick wall mounting, the flush mount box OD5 FBSDUR or OD10 FBSDUR is required (available
separately).
• Do not install the dummy module on unstable walls or on surfaces which cannot support the device's
weight.
• For acoustic reasons, the dummy module must be installed at a distance of min. 4 mm (0.16 in) to the
Intercom station.
• Make sure the mounting box is not subject to torsional forces (e.g. on uneven walls).
• No water may penetrate into the mounting box.
• The installation of the RFID reader within or its attachment to the dummy module must be done on site.
• Before using the device, ensure all cables are connected correctly and are not damaged.
• Use moistened microfibre cloths for cleaning the dummy module.
Safety instructions
• This device shall be installed or replaced by trained and qualified personnel only.
• Observe the country-specific standards for installation, mounting and configuration.
• Only Commend accessories that comply with the technical specifications shall be used.
• Replace the dummy module if the glass on its front is damaged.
Manufacturer's reference
For technical specifications, see the respective data sheet.
For the latest software and documentation, visit: www.commend.com
Keep this description in safe custody.
Type: D-BZ-OD-FBDUR, Version: V1.2/0921
Commend International GmbH, Saalachstraße 51, A-5020 Salzburg – www.commend.com
75 (2.95)
**
86 (3.39)
11 (0.43)
*
73 (2.87)
75 (2.95)
**
*
Projection on the wall
**
Wall cutout
***
Minimum mounting
distance to od5 / od10
**
86 (3.39)
*
Projection on the wall
**
Wall cutout
18 (0.71)*
***
Minimum mounting
78 (3.07)
distance to od5 / od10
Projection on the wall
*
Wall cutout
**
Minimum mounting
***
distance to od5 / od10
11 (0.43)
*
73 (2.87)
loading

Inhaltszusammenfassung für Commend OD5 FBDUR

  • Seite 2 • Bei Installation, Montage und Konfiguration die geltenden länderspezifischen Normen beachten. und 1,6 mm befestigt werden. • Es darf nur Zubehör von Commend verwendet werden, das den technischen Spezifika tionen des  Den Rahmen so ausrichten, dass die Sicherungsschraube beim OD5 FBDUR nach unten und beim Geräts entspricht.

Diese Anleitung auch für:

Od10 fbdur