P0
Save and exit menu
Inverter settings
It is set whether energy is to be drawn primarily from the
battery or from the mains or generator.
(01) Mains or generator primary: As soon as the
mains or a generator is connected to the ARVEY,
P1
the bypass is activated and the battery is charged.
(03) Battery primary: The inverter draws energy
preferentially from the battery. Only when the
battery is almost empty is it switched to the
connected mains or generator. The battery is not
charged.
- - -
P2
(menu item not assigned)
Battery charging current
P3
The charging current can be set to values between 0% and
100%.
Acoustic signals
You can switch acoustic signals on or off (On/Off setting).
P4
However, safety and operational signals always remain
active.
Function
4

Usage

4.1

Operating mode

The ARVEY E-Series has four operating modes, which are listed in the table
below. Depending on the connected power source, the operating mode is
switched automatically.
Operating mode
Function
Supply of the
Battery operation
consumers with
battery
Consumers are
Mains or
supplied by mains or
generator
generator. At the
operation
same time, the
battery is charged.
Consumers are
primarily supplied
Photovoltaics
with solar energy.
operation
Surplus energy is
used to charge the
battery.
Solar energy and grid
or generator power
are used
Mixed operation
simultaneously,
providing an ideal
power mix.
Symbols
29