3.2

Status display LEDs

The status LEDs show you information about the device.
LED
Status
On
Photovoltaic controller active
PV
green
Off
Photovoltaic controller not active
230 V input is connected and switched
On
through to the output (bypass)
LINE
green
230 V input is not connected or bypass is not
Off
active
Inverter is active and converts battery voltage
On
INV
yellow
to AC voltage
Off
Inverter is not active
An error has occurred. Please check the cause
On
with the help of the error code (see chapter 6)
FAU
red
Off
Device works without errors
3.3

Acoustic signals

The device has an internal speaker for outputting acoustic signals.
Status
Device works normal
When the device is started, it beeps 4 times.
If setting P4 is activated (see next chapter
"Settings"), additional beeps are emitted at regular
intervals.
Battery fully charged
The device beeps regularly 4 times briefly.
Battery low state-of-
The device regularly beeps 2 times briefly.
charge
Overtemperature,
The device beeps 2 times per second.
overload
Error (see chapter 6)
Fast interval sound.
Description
Acoustic signal
3.4

Settings

Press and hold the Funct key for 5 seconds to activate the settings menu. "P0"
then flashes at the top in the center of the display. Use the Up/Down keys to
scroll through the submenu P0 to P4 and activate it with the Funct key.
In the respective submenu, you can make settings with the Up/Down keys and
confirm them with the Funct key. Then navigate to "P0" to save and exit the
settings menu again.
Figure 16 Settings menu