Herunterladen Inhalt Inhalt Diese Seite drucken

Product Description; Power Source; Ambient Conditions - JESS Welding G450 S Betriebsanleitung

Schweißstromquelle
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

G450 S | G600 S
3.1.2 G600 S
Fig. 2
Tab. 2

Power source

Mains voltage, 3 phases
Fuse
Max. power consumption
Setting range
Operating voltage
Idle voltage
Duty cycle 35 %
Duty cycle 100 %
Protection type
Insulation class
Type of cooling
Weight
Dimensions L × W × H

3.1.3 Ambient conditions

The welding power source must only be operated at a temperature between −10°C and +40°C and at
a relative air humidity of up to 50 % at +40°C or up to 90 % at +20°C. The ambient air must be free
of unusually high quantities of dust, acids, corrosive gases or substances etc., other than those that arise
during the welding process.
BA-0003 • 2020-04-09
G600 S
G600 S technical data
• Manufactured in accordance with the European standards EN 60974-1 and EN 60974-10
G600 S
400 V, 50/60 Hz
63 A time-lag
50 kVA
35–600 A, continuous
21–44 V
80 V
600 A/44 V
350 A/34 V
IP22
H (180°C)
F
210 kg
810 × 500 × 850

3 Product description

EN - 7

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

G600 s

Inhaltsverzeichnis