Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Introduction; Function / Operation - Wilms CH 2000 Betriebsanleitung

Elektro heizer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Technical Data

Type
Voltage
Frequency
Rated Power
Nominal Current
Air Flow
Weight
Dimensions (mm)
Protection Class
Noise Level

4. Introduction

This device has a built-in room thermostat that senses the air temperature and regulates the ambient
temperature according to the set value.
The room thermostat switches the heating elements and the fan motor off when the set temperature is
exceeded and on again when the temperature falls below it.
The device has 1 fan stage and 2 heating stages (1200 W / 2000 W).
The built-in overheat protection shuts off the heating elements in case of overheating to ensure safety.
A tilt sensor on the bottom of the device also switches off all functions if the device tips over or is not on
level ground.
When using the heater for the first time, you may notice a slight emission of smoke. This is quite normal
and it stops after a short time.

5. Function / Operation

Set up the device so that it stands upright on a firm surface and at a safe distance from wet surroundings
and flammable objects.
Connect the device to the socket, observing the prescribed mains voltage.
The ventilating function (without heating) and the 2 heating stages
(1200 W / 2000 W) are selected with the switch button on the left.
The desired room temperature is set using the thermostat on the
right. When this temperature is reached, the heater and fan motor
switch off automatically.
Selector switch:
0
Position
Off
To switch off, set the selector switch to ventilation and the thermostat to maximum. Allow the device to cool
down sufficiently (at least 2 minutes) and then set the selector switch to 0. If you do not intend to use the
device for a long period of time, store it in accordance with point 7.
Position 1 Ventilating
220-240 V
50 Hz
2000 W
9,1 A
95 m³/h
1,4 kg
L 205 x W 130 x H 260
IP 20
50 dB(A)
Position 2 Heating 1200 W
Page 12 of 16
CH 2000
Control Lamp
Selector switch
Thermostat
Position 3 Heating 2000 W

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis