Herunterladen Inhalt Inhalt Diese Seite drucken

Bosch ANGLE EXACT 12V-12-400 Originalbetriebsanleitung Seite 20

Industrie-akkuschrauber
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7
20 | English
Do not continue to press the On/Off switch after the
u
power tool has automatically switched off. The battery
can be damaged.
Follow the instructions on correct disposal.
Removing the battery (see figure A)
To remove the battery (7), press both release buttons (11)
and pull the battery downwards out of the power tool. Do
not use force to do this.
Battery charge indicator (yellow LED)
Battery
Meaning
charge indic-
ator
Flashing
Charge the battery:
light + sound
You can only drive in 6 to 8 more screws.
Continuous
There is not enough capacity left to drive in
light + sound
another screw or the power tool has over-
loaded:
The power tool can no longer be switched
on.
– Remove the battery and replace it with a
battery that is fully charged.
Flashing
The power tool has overheated and
light
switched itself off:
– Wait a short while for the light to stop
flashing before switching the power tool
on again.
When the rechargeable battery (7) is inserted and the on/off
switch (8) is pressed, the battery charge indicator  displays
the battery's state of charge for 5 seconds.
Rechargeable battery charge in-
dicator
Green
Yellow
Red
Operating and storage conditions
The power tool is suitable only for operation at enclosed
work sites.
To ensure smooth operation, the permitted ambient temper-
ature should be between 0 °C and +45 °C, at a permitted rel-
ative humidity of between 20 and 95%, free of condensa-
tion.
Suspension device (see figure B)
You can use the hanging hook (12) to attach the power tool
to a suspension device.
– Fit the hanging hook (12) onto the power tool and make
sure it engages in the holes (13).
Regularly check the condition of the hanging hook and
u
the catch in the suspension device.
1 609 92A 6RK | (09.11.2021)
Fitting the 180 W angle head (see figure C)
These industrial cordless angle wrenches must be fitted with
an adapter and a compatible angled screw head (see "Tech-
nical Data", page 18) first.
– Place the 180 W angle head on the adapter and tighten it
with an open-ended spanner (16) against the spanner flat
on the cap nut (14). Hold the open-ended spanner (17)
against the spanner flat of the adapter (15).
The thread and flange thread must be free from grease
u
and the correct torque (see "Technical Data", page 18)
must be used so that the angle head cannot come loose.
– Turn the lock nut (18) all the way back in the direction of
the arrow a (left-hand thread).
– Then turn the adapter all the way back in the direction of
the arrow a (left-hand thread).
Never clamp the power tool to the housing shells.
u
– Turn the adapter back to the right until the angle head is
in the required position, a maximum of 360°.
– Fix the adapter in this position by turning the lock
nut (18) in the direction of the arrow c against the ad-
apter using a suitable tool (hook spanner DIN 1810 form
B size 25/28). Tighten the lock nut (18) to the correct
tightening torque (see "Technical Data", page 18). While
doing so, you must hold with a suitable tool.
The thread and flange thread must be free from grease
u
and the correct torque (see "Technical Data", page 18)
must be used so that the angle head cannot come loose.
– Hold the power tool with the open-ended spanner (17)
against the spanner flat (15) of the adapter.
Fitting the 12 V angle head (see figure D)
Capacity
These cordless angle wrenches must be fitted with a com-
patible angled screw head (see "Technical Data", page 18)
60–100 %
first.
30–60 %
The angled screw head (3) with tool holder (2) can be con-
0–30 %
tinuously adjusted by 360°.
– Turn the lock nut (18) all the way back in the direction of
the arrow a (left-hand thread).
Never clamp the power tool to the housing shells.
u
– Turn the angled screw head (3) in the direction of the ar-
row d as far as it will go onto the flange. Then turn back in
direction b until the required working angle is reached;
however, it should only be turned a maximum of one 360°
rotation.
– Fix the angled screw head (3) in this position by turning
the lock nut (18) in the direction of the arrow c against
the angled screw head using a suitable tool (hook spanner
DIN 1810 form B size 25/28). Tighten the lock nut (18)
to the correct tightening torque (see "Technical Data",
page 18). While doing so, a suitable tool (hook spanner
DIN 1810 form B size 20/22) must be hooked into an
opening on the angle head and held.
The thread and flange thread must be free from grease
u
and the correct torque (see "Technical Data", page 18)
must be used so that the angle head cannot come loose.
Bosch Power Tools

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Angle exact 12v-6-600Angle exact 12v-3-600

Inhaltsverzeichnis