Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Notes; Installation Instructions; Technical Data; Symbol Description - HANSGROHE PuraVida 15445 Gebrauchsanleitung, Montageanleitung

Rührgerät
Vorschau ausblenden Andere Handbücher für PuraVida 15445:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!

Symbol description

Do not use silicone containing acetic acid!
Adjustment (see page 35)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Cleaning (see page 36)
Dimensions (see page 38)
Fault
Mixer stiff
Mixer dripping
Diverter not operating
Hot water temperature too low, no
cold water. Instantaneous water
heater starts up when cold water is
selected.
4
English
+
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 60°C
70°C / 4 min
Cause
- Cartridge defective, calcified
- Cartridge defective
- Residue
- Water pressure to low
- Diverter defective
- Hot water limiter incorrectly set
- Crossflow
Assembly (see page 33)
Flow diagram (see page 39)
free flow
Shower outlet
Tub outlet
Spare parts (see page 40)
Special accessories (see page 40)
order as an extra
• extension 25 mm #13595000
• Extension Set 22 mm (when wall is not deep
enough) #13597XXX, #15597XXX,
#13593XXX
Operation (see page 37)
Test certificate (see page 48)
Remedy
- Exchange cartridge
- Exchange cartridge
- Clean converter / grease O-rings
- Increase water pressure
- Exchange diverter
- Set hot water limiter
- Exchange cartridge

Quicklinks ausblenden: