16. Troubleshooting

The following table shows fault symptoms and describes remedial measures in the event of your machine failing to
work properly. If you cannot localise and rectify the problem with this, please contact your service workshop.
Fault
Generator does not
start
Generator has
insufficient or no
voltage
28 | GB

Possible cause

Automatic oil cut-off starts
Spark plug sooty
No fuel
Electronics defective
Overload protection switch
tripped
Air filter dirty.
www.scheppach.com
Remedy
Check oil level, fill with engine oil as necessary.
Clean or replace spark plug.
Check electrode gap.
Top up with fuel.
Check fuel tap function.
Contact the specialist dealer
Restart generator.
Reduce consumption
Clean or replace filter if necessary.