Fuses
The fuse F1 is type 5x20 with a ceramic tube and flame quenching dust. The rating depends
on the following table:
Load:
2000W
Fuse:
T12,5A
supplied with the device
*
Leds
L1 Power on LED
L2 Transmitter code management LED
D1 7-segment display with two digits:
- "tr" means timer controlled activation of the output
- "On" means ON/OFF activation of the output
- "--" means the radio programmer is disabled
- Display OFF means the radio programmer is enabled and the output is at rest
When switched on the display will first of all show the firmware version ("r" "nn" where "nn" stands for
the version, e.g. "01") and then it will show the set time ("Hr" "Mn")
e.g. "Hr" "00" ; "Mn" "01", means the timer is set to 1 minute.
*
If led "L2" flashes continuously in groups of five the memory module is either missing or damaged.
If instead, led "L2" flashes continuously you will need to press down buttons "P1" and "P2" for 5
seconds until the led switches off.
Settings
J1 inserted: auxilliary output enabled - J1 disinserted: auxilliary output disabled
J2 inserted: rapida memorization enabled - J2 disinserted: rapida memorization disabled
1500W
T10A
*
*
1000W
T6,3A
15
750W
T5A