Transmitters
The transmitter is pre-coded and is fitted with an integrated circuit which is programmed in the
factory with a unique identification number. All the code parameters are contained in this integrated
circuit. The transmitter has an automatic shut down mechanism which cuts in after at least 20 seconds
of continuous use (this limits battery consumption).
Key block function
• A key block function has been added to protect the appliance from
accidental activation;
- to activate the function press and hold down "MR" for 8 seconds until
the orange led starts flashing, at this point to activate a command
you will need to press the required key three times consecutively;
- to reset the function to standard operation standard press and hold
down "MR" for 8 seconds until the orange led starts flashing.
Installation (fig. 4)
Work out the position in which the programmer will be situated
remembering that the site must be:
- a position safe from accidental collision;
- high enough above the ground to be safe from pools of water;
- in a position which the technician can easily reach.
The case is fixed using "fast-fitting" brackets. The bracket should be fixed to the wall using two
raw plugs "1" (check that it is square to the wall), the case can be then slid onto the bracket "2"
therefore fixing it to the wall. The slot-in circuit located towards the bottom of the case can be
easily extracted to facilitate wiring up the device. If any repair work is necessary the case can
be easily extracted by pushing upwards the action of which will separate it from the bracket.