3. When finished, the brine tank valve closes.
4. The next step is a rinse to wash any remaining salt from the filter.
2.5.4.
Rinsing the softening filter (takes about 3 minutes):
Press the button so that the control valve is in the position responsible
1.
for rinsing the softening filter.
2. The resin will be flushed in order to compress it, which results in higher
softening quality.
2.5.5.
Refilling (takes about 2 min.):

Press the button so that the control valve is in the position

1.
corresponding to filling the brine tank.
2. Make sure to fill the brine tank with enough water.
CAUTION! Only block salt is suitable for the salt solution. The use of edible table
salt is prohibited.
2.5.6.
Flushing the purification filter:
Press the button so that the control valve is in the position
1.
corresponding to rinsing the purification filter.
2. Residual activated carbon will be flushed out.
2.5.7
Treatment mode:
Press the button so that the control valve is in the position
1.
corresponding to the water treatment mode.
2. The unit will begin to purify and soften the water.