Eigensicherer stromschleifenkalibrator
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 25
Electrical Power Supply
Only use 4 x LR6 (size AA), Industrial By Duracell ID1500, Duracell PROCELL, Duracell PLUS,
ENERGIZER ULTIMATE or GP SUPERALKALINE LR6.
Physical
Dimensions........................................................................... 90 x 140 x 42 mm(3.5" x 5.5" x 1.7")
Weight (nominal) .......................................................................................... 460 grams (16.2 oz.)
Terminals ............................................................................................................... 4 mm sockets
Case .................................................................................................................. High impact ABS
Environmental ....................................................................................................................... IP40
Relative Humidity ........................................................................................................... 0 to 90%
Guide to supply and input/output
No. Parameter and conditions
Current measurement between mA and COM with external 24V. This mode of operation
1
inserts the apparatus in the current loop by breaking into the circuit and connecting mA
&
(positive) and COM (negative) into the circuit.
2
Current measurement between mA (24V) and mA with internal 24V. Terminal mA(24V)
3
provides the source of power to supply remote sensor. Special condition for safe use -
remote sensor MUST be isolated from all other sources of power.
Voltage measurement between V and COM.
4
Continuity measurement between V and COM. Special condition for safe use - remote
5
sensor MUST be isolated from all other sources of power.
Current generation between mA and COM with external 24V. This mode of operation
6
inserts the apparatus in the current loop by breaking into the circuit and connecting mA
(positive) and COM (negative) into the circuit.
Current generation between mA (24V) and mA with internal 24V. Terminal mA (24V)
7
provides the source of power to supply the remote sensor. Special condition for safe use -
remote sensor MUST be isolated from all other sources of power.
Supply and input/output parameter
Param.
1 2 3
&
U
30V
i
I
100mA
i
P
1W
i
U
6.51V
0
I
14mA
0
P
22mW
0
C
220pF# 220pF# 110pF
i
L
0
i
C
33nF
0
L
1.5mH
0
K0341 Revision B
4
0*
50V
0*
100mA
0*
1W
25.2V
6.51V
158mA
12mA
0.995W 20mW
0
0
53nF
10nF
500µH
1.5mH
Table 1
Table 2
5
6
0*
30V
0*
100mA
0*
1W
6.51V
6.51V
8mA
14mA
20mW
22mW
110pF
220pF# 220pF#
0
0
11µF
33nF
100mH 1.5mH
2
7
* Special condition for
0*
safe use
0*
0*
25.2V
158mA
0.995W
# 220pF consists of 110pF
@ 6.51 V max and
110pF @ 1.6V max.
0
53nF
500µH