Herunterladen Inhalt Inhalt Diese Seite drucken

IFM Electronic efector200 OG5061 Bedienungsanleitung Seite 9

Reflexlichtschranke og laser
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Set the sensitivity with object.
2
Press once.
The yellow and green LEDs go out for approx. 1s,
then flash again alternately.
Set the sensitivity without object.
3
Press once.
The yellow and green LEDs go out for approx. 1s,
then the green LED is on.
The unit is in the operating mode.
You can also proceed in reverse order: first setting without the object,
the object.
If the setting of the sensitivity is not possible (e.g. object signal and
background signal are about the same), the red LED flashes after
step 3 for approx. 2s. The unit then passes into the operating
mode with the sensitivity being unchanged.
Setting of the sensitivity with moving objects
Activate the programming mode of the unit.
1
Press for about 2s until the red LED flashes.
The red LED goes out; the yellow and green LEDs flash alternately.
The unit is in the programming mode.
then with