Installation in hazardous areas (Ex)

This page is not applicable for the SulfiLogger™ S1 sensor.
Special conditions apply for installations in hazardous areas.
Pay close attention to other Ex equipment used in conjunction
with the SulfiLogger™ X1 sensor and the PowerCom Box.
Observe the specifications in the ATEX certificates as well as
national and local regulations.
Use Zener barriers or Ex isolators for installations without the
PowerCom Box (Fig. 6).
The PowerCom Box must be installed in a safe area if the DC and/
or SCADA connectors are used.
Ground the sensor at the M6 thread or at the eye bolt if the cable
guard accessory is used (Fig. 5).

Special conditions of use

 The SulfiLogger™ X1 sensor must be grounded.
 The ambient temperature area for the SulfiLogger™ X1 sensor
is specified to: T
: -20°C to +60°C.
amb
 The SulfiLogger™ X1 sensor must not be disassembled.
 It is the end user's responsibility to select proper barriers for
the SulfiLogger™ X1 sensor.
 The PowerCom Box is for fixed installation. Protect it from
direct airflow causing a charge transfer.
 Do only clean the PowerCom Box with a moist cloth.
 Do not replace PowerCom Box batteries when an explosive
atmosphere is present.
Fig. 6 Hazardous areas
Sul Logger™ X1 sensor
without PowerCom Box
Zone 0
Safe area
Power / 4-20 mA
Barrier
Barrier
RS-232
* Optional
SulfiLogger™ sensor and PowerCom Box Installation Manual. Revision 112 (Valid from April 2022)
Sul Logger™ X1 sensor
with PowerCom Box
Zone 0
Power / 4-20 mA
Apparatus,
e.g. SCADA
RS-232
Fig. 3 SulfiLogger X1
SulfiLogger™ X1-BCDE-F
SulfiLogger A/S
Tueager 1
DK-8200 Aarhus N
Denmark
Conc. range:
Target gas:
Operating temp.:
Cal. gas:
Power:
FCC ID:
Tamb:
Power / 4-20 mA: Ui: 30 V, li: 100 mA, Ci: 0 nF, Li: 100 µH, Pi: 0.70W
RS-232:
North America:
Class I Zone 0 AEx ia IIC T4 Ga
Class I Division 1 Groups A-D T4
Ex ia IIC T4 Ga
-20°C to +60ºC
ETL21CA104799609X
IECEx:
Ex ia IIC T4 Ga
-20°C to +60ºC
IECEx ETL21.0072X
ATEX and UKCA:
II 1G Ex ia IIC T4 Ga
-20°C to +60ºC
ETL21ATEX0085X
ITS21UKEX0474X
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Fig. 4 PowerCom Box marking plate example
PowerCom Box
Sulf iLogger A/S
Tueager 1
DK-8200 Aarhus N
Power / 4-20mA:
RS-232:
Um: 60V
Fig. 5 Grounding connections
Sul Logger™ X1 sensor with PowerCom Box +
4-20 mA (SCADA) and/or DC power connected
Zone 1
Zone 0
Power / 4-20 mA
PowerCom
Box
marking plate example
2804
2585
S/N:
Disassembly of this device is not allowed.
Min. 12 VDC
Le démontage de cet appareil n'est pas
2ATWPSULFILOGGER1
autorisé.
-20°C to +60°C
Ui: 20 V, li: 100 mA, Ci: 0 nF, Li: 0 µH, Pi: 0.30W
Conforms To:
UL STD 60079-0
UL STD 60079-11
UL STD 61010-1
Certified To:
CSA STD C22.2#60079-0
CSA STD C22.2#60079-11
CSA STD C22.2#61010-1-12
Conforms To:
IEC STD 60079-0
IEC STD 60079-11
EN STD 60079-0
EN STD 60079-11
DTI 20ATEX0121X
2804
S/N:
II (1) G [Ex ia Ga] IIC
II 2(1) G Ex ib [ia IIC Ga] IIC T4 Gb
Uo: 28.5V, Io: 85mA, Po: 0.61W
Uo: 12.0V, Io: 85mA, Po: 0.26W
Safe area
PowerCom
Box
RS-232
EN
5022889
YYWW
SCADA /
DC power
* Optional
Page 3