Operating functions

The hand-held transmitter allows you to switch pumps on and off remotely and to adjust their
power.
• Provided there is a line of sight between transmitter and receiver, radio transmission of up to
80 metres is possible.
• Before it is possible to operate the unit with a transmitter, it is necessary to register (log in)
the transmitter on the receiver. You can register up to 10 transmitters on the receiver.
Functions of the hand-held transmitter
a
Digital display
• The display shows the power level set for the two pumps. (0 ... 100 %)
b
Buttons with the following functions:
• Register (log in) the transmitter on the receiver:
− Press button "b" on the receiver for approx. 1 s.
− Press button "d
• Save user-specific setting: See buttons "f"
• Delete all transmitters in the receiver: Press button "b" on the receiver for at least 5 s.
c
Function monitoring LED
• The LED lights up when a button is pressed on the transmitter.
d
ON/OFF button, pump 1
e
ON/OFF button, pump 2
f
Button for user-specific settings.
• Factory setting:
− f
: Pump power for both pumps = 25 %
0
− f
: Pump power for both pumps = 75 %
1
• Program user-specific setting:
− Use the buttons "d", "e" and "g" to set the condition you wish to call with button f
− Press button "b" on the receiver for approx. 1 second.
− Press button f
g
Dimmer
• Set pump power for both pumps. (0 ... 100 %)
" on the transmitter for at least 3 s.
0
or f
on the transmitter.
0
1