Electrical Precautions
WARNING!
!
EN
or death.
• 230 - 240V / AC - 50HZ – 0.4A.
• To protect against electric shock, do not immerse cord or plugs in water or other liquid.
• Unplug from the outlet when not in use and before cleaning. Allow to cool before putting on or
taking off parts.
• Do not operate any outdoor cooking gas appliance with a damaged cord, plug, or after the appli-
ance malfunctions or has been damaged in any manner. Contact the manufacturer for repair.
• If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
• Do not let the cord hang over the edge of a table or touch hot surfaces.
• Do not use an outdoor cooking gas appliance for purposes other than intended.
• When connecting, first connect plug to the outdoor cooking gas appliance then plug appliance into
the outlet.
• Use only a Ground Fault Interrupter (GFI) protected circuit with this outdoor cooking gas appliance.
• Never remove the grounding plug or use with an adapter of 2 prongs.
• Use only extension cords with a 3 prong grounding plug, rated for the power of the equipment, and
approved for outdoor use with a W-A marking.
Leak Testing Instructions
!
WARNING!
part of the gas system is replaced.
WARNING!
!
are in the area while you check for leaks. Sparks or open flames will result in a fire or explosion,
damage to property, serious bodily injury, or death.
Leak testing: This must be done before initial use, annually, and whenever any gas components are
replaced or serviced. Do not smoke while performing this test, and remove all sources of ignition. See
Leak Testing Diagram for areas to check. Turn all burner controls to the off position. Turn gas supply valve
on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one
recommended by the Napoleon Customer Solutions department and have the grill inspected by a certified
gas installer.
STOP
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill
inspected by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
www.napoleon.com
Failure to follow these instructions could result in property damage, personal injury
A leak test must be performed annually and each time a cylinder is hooked up or if a
Never use an open flame to check for gas leaks. Be certain no sparks or open flames