Herunterladen Inhalt Inhalt Diese Seite drucken

helvi PC EVO 76 Bedienungsanleitung Seite 15

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 50
to supply primary power to the system.
GROUND CABLE
Check for a solid ground cable connection to
the workpiece.
AUTOMATIC PURGE SYSTEM
Place the ON/OFF switch to the ON position.
Activate the torch button to initiate 3s gas
purge (pre-flow) to remove any condensation
that may have accumulated in the torch and
leads while the system was shut down. When
the gas purge is complete, pilot arc will be
initiated. To cool torch handle or to further
remove condensation in the torch and leads
push the torch gas purge button (B) on the
front panel of the unit.
WARNING
Do not initiate pilot arc during adjustment.
CHECKING AIR QUALITY
To check air quality, deactivate the torch (post-
flow) and place filter lens in front of the torch.
Any oil or moisture in the air will be visible
on the lens. DO NOT initiate pilot arc while
checking air quality.
OPERATION MODE SELECTION
Select the desired operation mode with the
selection key (A) in the control panel.
AIR PRESSURE REGULATION
Adjust the air pressure by pushing the air purge
button (B) and by acting on the air regulator (5).
Adjust the correct air pressure for each ope-
ration mode.
Torch 6m
EPT-106/H.70
Manaul cutting 3,5-4,5bar
Grid cutting
3,5-4,5bar
Gouging
2,5-4,0bar
CNC
3,5-4,5bar
For different torch length consider the following
pressure increases :
Torch Length EPT-106/H.70
10/12m
+0bar
20m
+0,4bar
30m
+0,7bar
The display shows the adjusted air pressure in
bars. If air pressure is correctly adjusted the
LED "OK" is on. If the LEDs "Increase" or "De-
crease" are on, adjust again the air pressure
until these get off and LED "OK" lights on.
CUTTING CURRENT REGULATION
Adjust the cutting current by acting on the ou-
tput current knob (2).
INITIAL SETUP
Once unit is powered on, the display will show
1.
2.
3.
4.
EP-126/166
CUTTING
5,0-5,5bar
5,0-5,5bar
CUTTING WITH A HAND TORCH
3,0-4,5bar
5,0-5,5bar
EP-126/166
+0,4bar
+0,9bar
+1,4bar
Figure 16
EN-11
"set" for a few seconds. In this time press the
left Selection key (A) to view the adjustable
parameters.
Use the central knob (2) and the right selec-
tion key (B) to choose, select and adjust the
parameter:
P1 - Pre-air safety.
Off = Arc starts immediately
On = Pre-air before the arc starts
On CNC cutting this safety can not be acti-
vated (off).
P2 - Torch length. Select 6, 10, 20 or 30 meters.
P3 - Type of torch. On the base of the type of
torch, the machine will adjust the secondary
parameters to optimize the performance and
the life of the consumable parts.
Pt -> EPT-106/H.70
PH1 -> EP-126
PH2 -> EP-166
According to the type of torch and to its length
the machine will also show the most suitable
air pressure range. The machine will automa-
tically recognize if a PT torch is connected. In
this case the air pressure parameter won't be
adjustable.
P4 - Torch Trigger Input. It selects the input
port to be used:
-> Default
-> trigger on CNC connector
-> the first pressed trigger gets auto-
matically selected
Use the right selection key to confirm the pa-
rameter adjustment and return to the pre-
vious menù.
To reset the parameters press and hold the
right selection key (B).
Use the left selection key to exit.
Select the non-continuous pilot arc mode with
the selection key (A) in the control panel.
The torch can be comfortably held in one
hand or steadied with two hands. Choose the
technique that feels most comfortable and
allows good control and movement. Position
the index finger or thumb to press the control
switch on the torch handle.
For edge starts, hold the torch perpendicular
to the workpiece with the front of the tip on
the edge of the workpiece at the point where
the cut is to start - Fig. 16.

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Pc evo 86Pc evo 126

Inhaltsverzeichnis