Troubleshooting

Water in or under the refrigerator
Fault
Water is leaking into the
inside of the
refrigerator.
Water is leaking onto
the floor.
Display signals
Signal
General error
The display blinks each
second.
Sensor failure
The display blinks and
shows "E1".
Low battery
The display blinks and
shows "E2" alternately
with the current temper-
ature.
10

Warranty

The statutory warranty period applies. If the product is defective, please contact your
retailer or the manufacturer's branch in your country (see dometic.com/dealer).
For repair and warranty processing, please include the following documents when
you send in the product:
• A copy of the receipt with purchasing date
• A reason for the claim or description of the fault
EN
Possible cause
The condensate drain duct is
clogged.
Medicines are preventing the water
from flowing to the collector.
There is too much water in the water
container.
Explanation
The display shows alternately the current inner temperature and
the active error code (fig. 2 1, page 3) (E1 or E2, see below).
The minimum and maximum values will be kept as the last known
values.
The minimum and maximum inner temperatures are still visible
and will be updated from the current inner temperature reading.
Troubleshooting
Remedy
Clean the drain.
Make sure that medicines
do not touch the rear
wall.
Clean the water
container.
21